IC693MDR390 | IC693MDR390C

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 9 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: 8 pt. 24Vdc Input Relay Output
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693MDR390 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

Series 90*-30 and PACSystems* RX3i IC693MDR390C, IC694MDR390A GFK-2657 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs Module June 2012 The 24 volt DC Input/Relay Output module provides eight isolated input points with one common power input terminal, and eight isolated normally-open relay circuits in the same module. The input circuits can have either positive or negative characteristics in that they sink or source current to/from the input devices to/from the user common. Input characteristics are compatible with a wide range of usersupplied devices, such as pushbuttons, limit switches, and electronic proximity switches. Current through an input results in a logic 1 in the input status table (%I). The relay output circuits are arranged in two groups of four circuits each. Each group has a common power output terminal. The normally-open relay circuits are used for controlling output loads provided by the user. The output switching capacity of each output is 2 amps. The relay outputs can control a wide range of user-supplied load devices, such as motor starters, solenoids, and indicators. The top half of the outside left edge of the insert is color-coded blue to indicate low-voltage circuits and the bottom half of the outside left edge is color-coded red to indicate high-voltage circuits. IC693MDR390 can be installed in any I/O slot in a PAC Systems RX3i or Series 90-30 PLC. IC694MDR390 can be installed in any I/O slot in a PAC Systems RX3i PLC System Module. IC694MDR390 cannot be installed in a Series 90-30 PLC system. Power for the internal relay circuits is provided by the +24 volt DC bus on the backplane. The user must supply the AC or DC power to operate field devices. There are no fuses on this module. 2 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs Module GFK-2657 Specifications Inputs Rated Voltage 24 volts DC Input Voltage range –30 to +32 volts DC Inputs per Module 8 (one group of eight inputs) Isolation 1500 volts RMS between field and logic side 500 volts RMS between inputs Input Current 7.5 mA (typical) at rated voltage Input Characteristics On-State Voltage 15 to 32 volts DC Off-State Voltage 0 to +5 volts DC On-State Current 4 mA (minimum) Off-State Current 1.5 mA (maximum) On Response Time 7 ms typical Off Response Time 7 ms typical Outputs Rated Voltage 24 VDC, 120/240 VAC Operating Voltage 5 to 30 volts DC 5 to 250 volts AC, 50/60 Hz Outputs per Module 8 (two groups of four outputs each) Isolation 1500 volts RMS between field and logic side 500 volts RMS between groups Maximum Load 1 2 amps maximum per output 4 amps maximum per common Minimum Load 10 mA Maximum Inrush 5 amps On Response Time 15 ms maximum Off Response Time 15 ms maximum Internal Power Consumption 80 mA (all I/O on) from +5V backplane bus 70 mA (all outputs on) from relay +24V backplane bus 1 Maximum load current is dependent on operating voltage as shown in the following table. For environmental specifications and compliance to standards refer to: RX3i: PACSystems RX3i Hardware and Installation Manual, GFK-2314 Series 90-30: Installation Requirements for Conformance to Standards, GFK-1179 Load Current Limitations for IC693MDR390 Operating Voltage Maximum Current for Load Type Typical Operations (number of operations) Resistive Lamp or Solenoid 2 240 VAC, 120 VAC, 24 VDC 2 amps 0.6 amps 200,000 240 VAC, 120 VAC, 24 VDC 1 amp 0.3 amps 400,000 240 VAC, 120 VAC, 24 VDC 0.5 amps 0.1 amp 800,000 2 For inductive loads. 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs Module 3 GFK-2657 Relay contact life, when switching inductive loads, will approach resistive load contact life if suppression circuits are used. The following figures are examples of typical suppression circuits for AC and DC loads. The 1A, 100V diode shown in the DC load typical suppression circuit is an industry standard 1N4934. The resistor and capacitor shown for AC load suppression are standard components, available from most electronics distributors. DC Loads DC Supply 1A, 100V Load Coil MDR390 ~ AC Source .022µF AC Loads 100 Ohms 600V 1/2W Load Coil MDR390 Installation in Hazardous Areas  EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS AREAS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS AREAS ONLY  WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;  WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS AREAS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND  WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. Indicators LED indicators that provide the ON/OFF status of each point are located at the top of the module. The LEDs are arranged in two horizontal rows with eight green LEDs in each row. The top row is labeled A1 through 8 (input points 1 through 8) and the bottom row is labeled B1 through B8 (relay output points 1 through 8). 4 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs Module GFK-2657 Field Wiring The following figure provides wiring information for connecting user supplied input and load devices, and power source(s) to the 24 Volt Input/Relay Output module. 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs Module 5 GFK-2657 Release History Release Date Comments IC694MDR390A June 2012 Initial release of RX3i version (with blue housing). IC693MDR390C August 2008 Updated agency compliance data Compatibility Programmer Version Requirements Description IC694MDR390 Proficy* Machine Edition (PME) version 7.0 SIM 11 or PME 7.50 and above IC693MDR390 Proficy* Machine Edition all versions GE Intelligent Platforms Contact Information Americas: 1-800-433-2682 or 1-434-978-5100 Global regional phone numbers are available on our web site www.g

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248