IC693MDL660 | IC693MDL660-BC

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 9 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: 24 VDC Input Module 32 Point (requires terminal block)
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693MDL660 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AB, -BC,

Product Manual Excerpt

Series 90™-30 IC693MDL660-BC GFK-2381B 24VDC 32-Point Positive/Negative Logic Input Module January 2010 The 24 VDC Positive/Negative Logic Input module, IC693MDL660, provides 32 discrete input points. The inputs are positive or negative logic inputs and will operate at levels up to 30V. The inputs are arranged in four isolated groups of eight; each group has its own common. Isolation is provided between the four groups of inputs, however each group of eight inputs is referenced to the same user common connection. Module MDL660 provides seven input filter times. Filter times can be set from the programmer using the module’s assigned output data references. When the module is used in a Series 90-30 system, filter time configuration is enabled by setting a DIP switch on the back of the module. Module MDL660 uses 48 input bits and 8 output bits to exchange point status and filter information with the CPU. This module can be used with either a Box-style (IC694TBB032) or Spring-style (IC694TBS032) front Terminal Block. The Terminal Block is ordered separately. 32 green LEDs indicate the ON/OFF status of points 1 through 32. The red/green TB LED is green when the module’s removable terminal block is locked in place. It is red when the terminal block is not locked. The blue bands on the label show that MDL660 is a low-voltage module. This module can be installed in any I/O slot in a Series 90-30 or PACSystems RX3i system. For CPU compatibility, refer to page 2. Release Information Upgrade Information Not applicable. Problems Resolved in this Revision 1. The module no longer becomes inoperable after a period of many rapidly-repeated power cycles. 2. (RX3i systems only): Hot Insertions that take longer than 1 second no longer cause a System Configuration Mismatch fault. (Series 90-30 does not support hot insertion/removal.) Warning Hot insertion/Hot removal: Do not insert or remove the module in any Series 90-30 backplane or a RX3i serial expansion backplane with power applied to the backplane. This could cause the PLC to stop or malfunction. Injury to personnel and damage to the module or backplane may result. If the PLC is in RUN mode, I/O data to/from this backplane will not be updated while power is removed. 1 2 3 4567 8 9 10 11 12 13 14 15 16 F 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 TB I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16 I17 I18 I19 I20 I21 I22 I23 I24 I25 I26 I27 I28 I29 I30 I31 I32 IC693MDL660 2 24VDC 32-Point Positive/Negative Logic Input Module GFK-2381B Known Restrictions and Open Issues in this Release Problem (RX3i systems only): Hot insertion/remove of the IC694MDL660 module may very rarely result in Terminal Block loss/add fault message Recommendation: If this happens, manually check Terminal Block presence. If the Terminal Block is present and locked, ignore Terminal Block loss/add fault message. Release History Release RX3i Compatibility Series 90-30 Compatibility IC693MDL660-A (Initial Release) Compatible with PACSystems RX3i CPU 2.9 firmware only. IC693MDL660-AB Compatible with PACSystems RX3i CPU 3.0 firmware or later. IC693MDL660-BC Compatible with PACSystems RX3i CPU 3.0 firmware or later. IC693CPU313, IC693CPU323, IC693CPU340, and higher with any firmware version IC693CPU311 and IC693CPU321with firmware version 2.02 or later (revision F or later) IC693CPU331 with firmware version 2.02 (revision G) or later Enabling Filter Time Configuration in a Series 90-30 System The MDL660 has one DIP switch on back of the module, which enables or disables filter time configuration from the Series 90-30 CPU. The RX3i ignores the setting of this switch. The module must be removed from the backplane to set the switch. The DIP switch setting must match the selection in the module’s software configuration. If the selection in the software configuration does not match the DIP switch setting, a fault occurs. Input Filter configuration DIP Switch Closed (left) = Enabled Open (right) = Disabled Not used In a Series 90-30 system, the Input Filter DIP switch must be set to Enabled for the CPU to be able to send input filter time configuration to the module. If the Input Filter switch is enabled, the CPU sends 32 bits of data, only 8 bits of which is used by the module. The other 24 bits are ignored. If the Input Filter switch is disabled, no data is sent from the Series 90-30 CPU to the module. The following table lists the binary values corresponding to the input filter times supported by the module. Digital Input Filter Times Binary Value Filter Value 0000 0000 0.5msec (default) 0000 0001 1msec 0000 0011 2msec 0000 1001 5msec 0001 0011 10msec 0101 0011 50msec 1100 0111 100msec 24VDC 32-Point Positive/Negative Logic Input Module 3 GFK-2381B Specifications: MDL660 Note: For installation in an RX3i system, refer to the PACSystems RX3i System Manual, GFK-2314. For installation in a 90-30 system, refer to the Series 90-30 Installation Manual, GFK-0356 and Installation Requirements for Conformance to Standards, GFK-1179. Environmental Specifications Vibration IEC60068-2-6, JISC0911 10 - 57 Hz, 0.012 displacement peak-peak 57 - 500 Hz, 1.0g acceleration Shock IEC60068-2-27, JISC0912 15G, 11ms Operating Temperature 0°C to 60°C: [inlet] (32° to 140°F) Storage Temperature -40°C to +85°C (-40° to 185°F) Humidity 5% to 95%, non-condensing Standards EMC EMISSIONS Radiated, Conducted CISPR 11/EN 55011 Industrial Scientific & Medical Equipment (Group 1, Class A) 47 CFR 15 Referred to as FCC part 15, Radio Devices (Class A) EMC IMMUNITY Electrostatic Discharge EN 61000-4-2* ±8KV Air, ±4KV Contact EN 61000-4-3* 10Vrms RF Susceptibility /m, 80Mhz to 1000Mhz, 80% AM, 1kHz sine wave ENV 50140/ ENV 50204 10Vrms /m, 900 ± 5Mhz, 100% PM, 200Hz square wave Fast Transient Burst EN 61000-4-4* ±1kV Voltage Surge EN 61000-4-5* Unshielded I/O Signal: ±1kV (42Ω) CM, ±0.5KV (42Ω) DM Damped Oscillatory Wave ANSI/IEEE C37.90a, EN61000-4-12* ±2.5KV CM/DM (200Ω) 1Mhz, 400Hz repetition rate, 1 min. Conducted RF EN 61000-4-6* AC/DC Input Power, Signal: 10Vrms, 0.15 to 80Mhz, 80%AM *EN61000-4-x series of tests are technically equivalent to the IEC61000-4-x series. 4 24VDC 32-Point Positive/Negative Logic Input Module GFK-2381B Performance Specifications Rated Voltage 24 volts DC Input Voltage Range 0 to 30 0volts DC Inputs per Module 32 (four isolated groups of 8 inputs) Isolation, Field to Backplane (optical) 250 VAC continuous; 1500 VAC for one minute Isolation, Group to Group 250VAC continuous; 1500 VAC for one minute Input Current 7.0 mA per point (typical) at rated voltage Board ID With Input Filter DIP switch disabled (default): 0x0F With Input Filter DIP switch enabled: 0x1A Input Characteristics: On–state Voltage 11.5 to 30 VDC Off–state Voltage 0 to 5 VDC On–state Current 3.2mA minimum Off–state Current 1.1mA maximum Input Filter Times 0.5ms, 1.0ms, 2.0ms, 5ms, 10ms, 50ms and 100ms, selectable per module On response Time 0.5ms, 1.0ms, 2.0ms, 5.0ms, 10.0ms, 50.0ms & 100.0ms (as per filter setting) Off response Time 0.5ms, 1.0ms, 2.0ms, 5.0ms, 10.0ms, 50.0ms & 100.0ms (as per filter setting) Power Consumption 300mA (all inputs on) from 5 volt bus on backplane Diagnostics Terminal block presence reported to RX3i CPU UL Class 1 Division 2 Hazardous Location Requirements The following statements are required to appear for Class I Div 2 Hazardous Locations. EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C, and D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON–HAZARDOUS LOCATIONS ONLY. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. WARNING – EXPLOSION HAZARD – DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON–HAZARDOUS. Control circuit modules require one No. 14 through 22 AWG or two No. 16 through 22 AWG stranded or solid copper conductors. The tightening torque range for the control terminals is 9.6-11.5 in. lb. Use only wire rated for 90°C. Observe any additional ratings that are provided with the modules. Use Filler modules in any unused slots in the chassis. 24VDC 32-Point Positive/Negative Logic Input Module 5 GFK-2381B Field Wiring: MDL660 Connections Terminals Terminals Connections Input 1 1 19 Input 17 Input 2 2 20 Input 18 Input 3 3 21 Input 19 Input 4 4 22 Input 20 Input 5 5 23 Input 21 Input 6 6 24 Input 22 Input 7 7 25 Input 23 Input 8 8 26 Input 24 Common 1 - 8 9 27 Common 17 - 24 Input 9 10 28 Input 25 Input 10 11 29 Input 26 Input 11 12 30 Input 27 Input 12 13 31 Input 28 Input 13 14 32 Input 29 Input 14 15 33 Input 30 Input 15 16 34 Input 31 Input 16 17 35 Input 32 Common 9 - 16 18 36 Common 25 - 32 Field Wiring Terminals Field Wiring 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 Input 18 Input 19 Input 20 Input 21 Input 22 Input 23 Input 24 Input 25 Input 26 Input 27 Input 28 Input 29 Input 30 Input 31 Input 32

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248