  • Description: GE Fanuc Series 90-30 48 Volts DC Input Pos/Neg Logic IC693MDL
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693MDL648 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

Series 90*-30 and PACSystems* RX3i IC693MDL648, IC694MDL648 GFK-2080A 48 VDC 16-Point Positive/Negative Logic Input Module June 2012 The MDL648 16-Point Isolated Input module provides 16 isolated input points in one group with a common power input terminal. The ON and OFF response times for this module are 1 mSec maximum. This input module is designed to be used in either positive logic or negative logic applications. Input characteristics are compatible with a wide range of user-supplied input devices, such as pushbuttons, limit switches, and electronic proximity switches. Current flow into an input point results in a logic 1 in the Controller’s input status table (%I). An insert fits between the inside and outside surface of the module’s hinged cover. The back of the insert has circuit wiring information, and circuit identification information can be written on the front of the insert. The front left edge of the insert is color-coded blue to indicate a DC-type module. IC693MDL648 can be installed in any I/O slot in a PAC Systems RX3i or Series 90-30 PLC. IC694MDL648 can be installed in any I/O slot in a PAC Systems RX3i PLC System Module. IC694MDL648 cannot be installed in a Series 90-30 PLC system. Power to operate input devices must come from an external 48 VDC power source supplied by the user. Specifications Rated Voltage 48 volts DC Input Voltage Range 0 to 60 volts DC Inputs per Module 16 (one group with a single common) Isolation 1500 volts between field side and logic side Input Current 4.2 mA (typical) at rated voltage Input Characteristics On–state Voltage 34 to 60 volts DC Off–state Voltage 0 to 10 volts DC On–state Current 3 mA minimum Off–state Current 1.1 mA maximum On response Time 1 ms maximum Off response Time 1 ms maximum Power Consumption: 5V 80 mA (all inputs on) from 5 volt bus on PLC backplane Power Consumption: 48V 74 mA from the user-supplied 48VDC power supply For environmental specifications and compliance to standards refer to: RX3i: PACSystems RX3i Hardware and Installation Manual, GFK-2314 Series 90-30: Installation Requirements for Conformance to Standards, GFK-1179 2 48 VDC 16-Point Positive/Negative Logic Input Module GFK-2080A Installation in Hazardous Areas  EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS AREAS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS AREAS ONLY  WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;  WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS AREAS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND  WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. Indicators LED indicators that provide the ON/OFF status of each point are located at the top of the module. This LED block has two horizontal rows with eight green LEDs in each row; the top row is labeled A1 through 8 (points 1 through 8) and the bottom row is labeled B1 through 8 (points 9 through 16). Field Wiring The following figure provides wiring information for connecting user-supplied input devices and power source to the 48 volt DC positive/negative logic input module. 48 VDC 16-Point Positive/Negative Logic Input Module 3 GFK-2080A Input Points vs. Temperature for MDL648 60V Supply 48V Supply a45135A 16 12 8 4 10C 20C 30C 40C 50C 60C Ambient Temperature (°C) Number of Inputs On Release History Release Date Comments IC694MDL648A June 2012 Initial release of RX3i version (with blue housing). . IC693MDL648C July 2007 Updated agency compliance data Compatibility Programmer Version Requirements Description IC694MDL648 Proficy* Machine Edition (PME) version 7.0 SIM 11 or PME 7.50 and above IC693MDL648 Proficy* Machine Edition all versions GE Intelligent Platforms Contact Information Americas: 1-800-433-2682 or 1-434-978-5100 Global regional phone numbers are available on our web site www.ge-ip.com www.ge-ip.com ©Error! Reference source not found. GE Intelligent Platforms, Inc. All Rights Reserved *Trademark of GE Intelligent Platforms, Inc. All other brands or names are property of their respective holders. GFK-2080A

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248