IC693MDL250 | IC693MDL250-AA

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693MDL250 | IC693MDL250-AA

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: 16 PT 120 VAC ISOLATED
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693MDL250 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -BA, -CA,

Product Manual Excerpt

Series 90™-30 IC693MDL250 GFK-2366 120VAC 16-Point Isolated Input Module October 2005 The 120VAC 16-Point Isolated Input module, IC693MDL250, provides 16 isolated input points. Input points can be used on different phases of the AC supply or powered from the same supply. An RC snubber protects each input against transient electrical noise on the power line. The module’s input filtering time can be changed during system operation by the application program. No DIP switch settings are required. When the module is used in a Series 90-30 system, filter time configuration is enabled by setting a DIP switch on the back of the module. This module can be used with a Box-style (IC694TBB032), Extended Box-style (IC694TBB132), Spring-style (IC694TBS032), or Extended Spring-style (IC694TBS132) Terminal Block. Extended terminal blocks provide the extra shroud depth typically needed for field wiring to AC devices. See the PACSystems RX3i System Manual, GFK-2314 revision B or later for more information about Terminal Blocks. Terminal Blocks are ordered separately. Individually numbered LEDs show the ON/OFF status of each Input point. The TB LED is green when the module’s removable terminal block is locked in place. It is red when the terminal block is not locked. This module can be installed in any I/O slot in a Series 90-30 or PACSystems RX3i system. It must be used with RX3i CPU release 3.50 or later. For compatible Series 90-30 CPUs, see CPU Compatibility on page 2. Specifications: IC693MDL250 Rated Voltage 120VAC Input Voltage Range 0 – 132VAC (47 to 63 Hz), 120VAC nominal Inputs per Module 16 isolated Isolation Field to Backplane 250 VAC continuous; 1500 VAC for 1 minute Group to Group 250 VAC continuous; 1500 VAC for 1 minute Input Current 7.0 mA per point (typical) at rated voltage Input Filter Times 20 msec – 2540 msec in 20 msec increments. Sent from CPU. Enabled by DIP switch. Power Consumption 220mA (with all inputs on) from 5 volt bus on backplane Input Characteristics: On–state Voltage 70-132VAC Off–state Voltage 0 to 20VAC On–state Current 5mA minimum Off–state Current 2.5mA maximum On/Off Response Time +0–1 AC cycles for filter times up to 840ms +1–2 AC cycles for filter times of 840ms to 1600ms +2–3 AC cycles for filter times of 1600ms to 1920ms +3–4 AC cycles for filter times of 1920ms or more 1 2 3 4567 8 9 10 11 12 13 14 15 16 TB I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16 IC693MDL250 For product standards and general specifications, refer to Appendix A of the PACSystems RX3i System Manual, GFK-2314 or GE Fanuc Product Agency Approvals, Standards, General Specifications, GFK-0867 (Series 90-30 systems). 2 120VAC 16-Point Isolated Input Module GFK-2366 CPU Compatibility Family Model Firmware Version RX3i All 3.5 and later Series 90-30 CPU350 CPU352 CPU364 CPU374 10.60 or later 10.50 or later 10.60 or later 11.03 or later Release History Version Description IC693MDL250-AA Firmware version: 1.10 Initial release Installation in Hazardous Locations WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES. WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY. 120VAC 16-Point Isolated Input Module 3 GFK-2366 Enabling Filter Time Configuration in a Series 90-30 System The MDL250 has one DIP switch on back of the module, which enables or disables filter time configuration from the Series 90-30 CPU. If the Input Filter switch is enabled, the CPU sends 32 bits of data, only 8 bits of which is used by the module. The other 24 bits are ignored. If the switch is disabled, no data is sent from the Series 90-30 CPU to the module. The module must be removed from the backplane to set the switch. The module’s software configuration must match the DIP switch setting. The RX3i ignores the setting of this switch. When the module is used in an RX3i system, the input filter settings are enabled or disabled using the software configuration. Input Filter configuration DIP Switch Closed (left) = Enabled Open (right) = Disabled Not used Input Filter Setup If an input filter time should be applied to all the module’s inputs, input filtering should be enabled in the module’s software configuration. The Digital Filter Settings Length must be to 16, and a memory location to be used for the filter value must be specified. Configuring a Digital Filter Settings Length of 0 disables the input filter. During system operation, the input filter time can be changed from the programmer by entering a filter setting value from 1 to 127 decimal (1hex to 7Fhex) into the assigned memory location. This filter setting value is equal to the new filter time divided by 20 decimal. For example, to change the filter time to 200ms, enter the value 10dec (0Ahex) into the memory location. Some example filter times and their hexadecimal setting values are listed below. Setting (hexadecimal) Filter Time in milliseconds Setting (hexadecimal) Filter Time in milliseconds Setting (hexadecimal) Filter Time in milliseconds 0A 200 21 660 5A 1800 0F 300 22 680 5F 1900 11 340 2A 840 71 2260 12 360 2F 940 72 2280 1A 520 51 1620 7A 2240 1F 620 52 1660 7F 2540 4 120VAC 16-Point Isolated Input Module GFK-2366 Field Wiring: MDL250 Field wiring connections to the module are made to the removable terminal assembly, as described in the RX3i System Manual, GFK-2314 and the Series 90-30 Installation Manual, GFK-0356. Connections Terminals Terminals Connections Input 1 1 19 Input 9 Input 1 Return 2 20 Input 9 Return Input 2 3 21 Input 10 Input 2 Return 4 22 Input 10 Return Input 3 5 23 Input 11 Input 3 Return 6 24 Input 11 Return Input 4 7 25 Input 12 Input 4 Return 8 26 Input 12 Return Input 5 9 27 Input 13 Input 5 Return 10 28 Input 13 Return Input 6 11 29 Input 14 Input 6 Return 12 30 Input 14 Return Input 7 13 31 Input 15 Input 7 Return 14 32 Input 15 Return Input 8 15 33 Input 16 Input 8 Return 16 34 Input 16 Return No connection 17 35 No connection No connection 18 36 No connection Field Wiring Terminals Field Wiring 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 I1 I1RTN I2 I2RTN I3 I3RTN I4 I4RTN I5 I5RTN I6 I6RTN I7 I7RTN I8 I8RTN NC NC H N H N H N H N H N H N H N H N H N H N H N H N H N H N H N H N ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ I9 I9RTN I10 I10RTN I11 I11RTN I12 I12RTN I13 I13RTN I14 I14RTN I15 I15RTN I16 I16RTN NC NC

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248