IC693CPU360 | IC693CPU360-DJ

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU360 | IC693CPU360-DJ

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 8 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 CPU Module without serial ports
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU360 : -BA, -BB, -BC, -BD, -BE, -CF, -CG, -CH, -DH, -DJ, -DK, -EK, -EL,

Product Manual Excerpt

March 11, 2006 GFK-1512N IMPORTANT PRODUCT INFORMATION READ THIS INFORMATION FIRST Product: Series 90-30 CPU Modules with Firmware Release 10.73 IC693CPU350-DH IC693CPU360-DJ IC693CPU363-CJ Firmware version 10.73 is a maintenance release for the CPU modules listed above. The changes in this release are described in “Problems Resolved by this Revision” and “New Features and Enhancements” on page 2. Upgrades If you wish to upgrade an existing CPU350, CPU360 or CPU363 to firmware version 10.73, you may purchase the applicable kit or download at no charge from http://globalcare.gefanuc.com/. Firmware upgrades require the IC690ACC901 Miniconverter and Cable Kit. Firmware Upgrade Kit Catalog Numbers CPU Catalog Number Firmware Upgrade Kit Catalog Number IC693CPU350-DH 44A747145-G07 IC693CPU360-DJ 44A747148-G08 IC693CPU363-CJ 44A747766-G08 Product Documentation Series 90-30 PLC Installation and Hardware Manual, GFK-0356 Series 90-30 CPU Reference Manual, GFK-0467 Functional Compatibility  Machine Edition PLC Logic Developer version 2.11 or later, or VersaPro version 2.02 or later should be used to configure and program these CPU models.  Version 4.00 or later of the C toolkit must be used for C programming.  All Ethernet Interface (IC693CMM321) modules used for programmer or HMI/SCADA communications with this CPU must be one of the following revision groups: IC693CMM321-CC or later IC693CMM321-AA or -BA upgraded to firmware version 1.11 or later  The CPU363 model does not support configuration of communications (other than SNP Slave through the power supply port) using the Hand-Held Programmer (HHP).  IC693BEM340 firmware version 3.00 or later is required for this release of CPU firmware. 2 Important Product Information GFK-1512N Problems Resolved by this Revision Subject Description CPU Software Fault from MOVE_REAL Function Block Previously, a CPU software fault could occur when a MOVE_REAL function block was executed with certain IN and Q parameters. This problem has been corrected. Config Not Equal With IC693DSM324 Previously, certain versions of programming software displayed Config NE (not equal) after a hardware configuration that contained an IC693DSM324 module was stored. This problem has been corrected. Sign of PID Derivative Term Corrected in One Case Previously, when the DERIVATIVE_ACTION bit (bit 3) was set in the Config Word, but the ERROR_TERM_SELECT bit (bit 0) was not set, the sign of the derivative term was reversed. This problem has been corrected. See “Documentation Errata“ on page 4 for related information. PID Integral Contribution Previously, a large step change of the PID Integral Contribution could occur when the integral rate was changed while the PID control loop was active. The Integral Contribution is now calculated correctly for all integral rates. New Features and Enhancements Subject Description Filtering Added for PID Derivative Term Optional filtering may now be applied to the PID Derivative Term to improve control loop stability in some applications. Filtering may be enabled by setting bit 5 (previously unused) in the Config Word parameter of the PID Parameter Block. See “Documentation Errata“ on page 4 for more information. Restrictions and Open Issues Subject Description Timing Issue with ALG220/221 Modules May Result in Incorrect %AI Values Read by CPU The %AI values reported by an IC693ALG220/221-F or earlier module revision may be incorrect and exhibit erratic behavior. Certain current or voltage levels within the input range applied to the module can cause the %AI values to be reported incorrectly. The problem stems from the use of particular optocouplers that may exhibit timing issues with CPU 35x/36x modules. This issue does not occur with IC693ALG220/221-G and later module revisions. The CPU may generate a fatal fault if logic containing a DOIO function block call to a smart module is repeatedly transitioned between RUN and STOP modes. Storing program logic that contains a call to a DOIO function block may cause the CPU to run out of system memory. This can occur when the PLC transitions between RUN and STOP modes several times. Storing the hardware configuration will cause the system memory to be freed, and the PLC will resume normal operation. CPU may generate a Fatal Fault during store of folders with large configurations The CPU may generate a fatal fault during a store of a folder with a very large configuration. This may be made worse by storing logic and configuration at the same time, or by read requests for reference table data from a programmer or HMI during the store. See “Storing Large Configurations” on page 3 for recommendations. Reading corrupted data from flash memory may cause a Watch Dog Timeout If corrupted data is read from flash memory, the Watch Dog Timer on the PLC may be triggered. This can be corrected by completing a valid flash store. Important Product Information 3 GFK-1512N Subject Description The CPU may generate a fatal fault when configuring a module with the HHP following a store to the PLC that exhausts user memory The 9030 PLC CPU may generate a fatal fault when the user attempts to configure a module with the HHP after a store to the PLC that exhausts user memory. Firmware Update Fail Following Power-up with Clear M/T and a Write to Flash A firmware upgrade may fail after the user presses the Clear and M/T keys on the HHP during power-up and then performs a write to flash. Cycling power on the PLC will enable the upgrade to proceed. CPU363 ports 1 and 2 do not handle parity errors in accordance with the SNP specification. The SNP specification requires both slave and master devices to reply to messages that contain parity errors with a 2-byte NACK message indicating a BCC or Parity Error (code 0). The NACK triggers a re-try transmission from the communications partner. For CPU363 ports 1 and 2 however, parity errors are fatal. The ports do not send the NACK message as expected, and the SNP master must send a new Attach message to re-establish communications. During the time between the parity error and the new Attach message, CPU363 ports 1 and 2 do not respond to COMMREQs from the PLC application. For example, attempting to use a serial port setup COMMREQ to change the parity setting will fail if the first Attach message with parity that is different from the hardware configuration arrives at the port before the COMMREQ. If the master re-tries Attach messages more often than every 12 seconds, the COMMREQ will not be processed until the master stops sending Attach messages or the SNP cable is disconnected. Operational Notes Subject Description User Information Cleared when Upgrading Firmware User information, consisting of program, configuration, CPU ID (used for SNP communications), and status tables in RAM memory, will automatically be cleared if the CPU firmware in flash memory is changed. You will need to restore these if upgrading firmware. The user program, configuration, and reference memory (%R, %AI, %AQ, %I, %Q, %T and %M) tables can be restored from a PLC programmer folder or from flash. The SNP ID must be set separately, using the PLC programmer or the HHP. The faults, overrides and transition tables cannot be stored to flash. The overrides may be restored from the programmer or folder, but the faults and transitions are lost. Writing to Flash Memory When writing very large programs to flash memory, it may be necessary to increase the request timeout value in the programming software to avoid receiving a request timeout message. An upper bound of 25 seconds is typically satisfactory Storing Large Configurations A Series 90-30 PLC using a CPU 36x supports a maximum of 32 DSM314 or DSM324 modules. This number is reduced when other intelligent modules are used in the PLC, such as APM and GBC modules. It may also be reduced when: The number of racks in the PLC increases; The total size of logic, motion and AUP files increases; The application uses C logic blocks or a C logic program; or Connected programmers or HMI devices are used to read reference memory or fault tables. In some cases it may be possible to increase the number of DSM314 or DSM324 modules that the CPU will accept in the hardware configuration by storing logic first and then storing the configuration separately. 4 Important Product Information GFK-1512N Subject Description CPU350 and CPU36x Do Not Support Hardware Configurations For CPU31x/32x/33x/34x/374 An application that contains any CPU35x or CPU36x model in the hardware configuration can usually be stored to any other release 9.00 or later CPU35x or CPU36x model and then executed. However, attempting to store a hardware configuration that contains a CPU31x, 32x, 33x, 34x or 374 to a CPU35x or CPU36x will fail. Simultaneous Load and Store When operating with multiple programmers attached, if a store operation is initiated by one programmer, while a load operation is already in progress, the load request will fail. Transition Tables are not cleared when the reference tables are cleared. The transition tables are not cleared upon clearing the reference tables through the programmer. Documentation Errata Series 90-30 CPU Instruction Set Reference Manual The following changes will be made to the Series 90™-30/20/Micro PLC CPU Instruction Set Reference Manual, GFK-0467M, at its next revision: In Chapter 12, ”Control Functions”, Section “PID Algorithm Selection (PIDISA or PIDIND) and Gains” The description of the Derivation term should be replaced with this text: The Derivative term is the time rate of change of the Error term in the interval since the last PID solution. Derivative = ∆Error / dt = (Error – previous Error) / dt, where dt = Current PLC elapsed time - PLC elapsed time at previous PID solution. In normal mode (that is, without Reverse-Action mode), this is the change in the error term. (Error – previous Error) = (SP – PV) – (previous SP – previous PV) = (previous PV – PV) – (previous SP – SP) However, when the Error Polarity bit (bit 0) in the Config Word is set, the sign of the change in the error term is reversed. (Error – previous Error) = (PV – SP) – (previous PV – previous SP) = (PV – previous PV) – (SP – previous SP) The change in the error term depends on changes in both the Set Point and the Process Variable. If the Set Point is constant, the difference between SP and the previous SP is zero and has no effect on the output. However, Set Point changes can cause large transient swings in the derivative term and hence the output. Loop stability may be improved by eliminating the effect of Set Point changes on the derivative term. Set the third bit (bit 2) of the Config Word to 1 to calculate the Derivative based only on the change in PV. For bit 2 set in normal mode (bit 0 = 0), (Error – previous Error) = (previous PV – PV), and with bit 2 set in Reverse-Action mode (bit 0 = 1), (Error – previous Error) = (PV – previous PV). For information about a related issue, see “Sign of PID Derivative Term Corrected in One Case” in “CPU Problems Resolved by this Revision” on page 2. Important Product Information 5 GFK-1512N In table 12-13 on page 12-82 of GFK-0467M, the Config Word row should be replaced with: %Ref+0012 Config Word Low 6 bits used Bit 0: Error Polarity. When this bit is 0, the error term is SP - PV. When this bit is 1, the error term is PV - SP. Setting this bit to 1 modifies the standard PID Error Term from the normal (SP – PV) to (PV – SP), reversing the sign of the feedback term. This is for reverse acting controls where the CV must go down when the PV goes up. Bit 1: Output Polarity. When this bit is 0, the CV output represents the output of the PID calculation. When it is set to 1, the CV output represents the negative of output of the PID calculation. Setting this bit to 1 inverts the Output Polarity so that CV is the negative of the PID output rather than the normal positive value. Bit 2: When this bit is 1, the setpoint is removed from derivative calculation. For details, see the discussion on page 15. Bit 3: Deadband action. When the Deadband action bit is 0, no deadband action is chosen. If the error is within the deadband limits, the error is to be zero. Otherwise the error is not affected by the deadband limits. If the Deadband action bit is 1, deadband action is chosen. If the error is within the deadband limits, the error is forced to be zero. If, however, the error is outside the deadband limits, the error is reduced by the deadband limit (error = error – deadband limit). Bit 4: Anti-reset windup action. When this bit is 0, the anti-reset windup action uses a reset back calculation. When the output is clamped, this replaces the accumulated Y remainder value with whatever value is necessary to produce the clamped output exactly. When the bit is 1, this replaces accumulated Y term with the value of the Y term at the start of the calculation. In this way, the pre-clamp Y value is held as long as the output is clamped. Bit 5: Enable derivative filtering. When this bit is set to 0, no filtering is applied to the derivative term. When set to 1, a first order filter is applied. This will limit the effects of higher frequency process disturbances on the derivative term. 6 Important Product Information GFK-1512N IC693CPU350 Data CPU Type Single slot CPU module Total Baseplates per System 8 (CPU baseplate + 7 expansion and/or remote) Load Required from Power Supply 670 milliamps from +5 VDC supply Processor Speed 25 MegaHertz Processor Type 80386EX Typical Scan Rate .22 milliseconds per 1K of logic (Boolean contacts) User Program Memory (maximum) 48K Bytes (not configurable) Discrete Input Points - %I 2,048 Discrete Output Points - %Q 2,048 Discrete Global Memory - %G 1,280 bits Internal Coils - %M 4,096 bits Output (Temporary) Coils - %T 256 bits System Status References - %S 128 bits (%S, %SA, %SB, %SC - 32 bits each) Register Memory - %R 9,999 words Analog Inputs - %AI 2,048 words Analog Outputs - %AQ 512 words System Registers (for reference table viewing only; cannot be referenced in user logic program) 28 words (%SR) Timers/Counters >2,000 Shift Registers Yes Built-in Serial Port(s) 1 (uses connector on PLC power supply). Supports SNP, SNP-X slave protocols. Requires CMM module for SNP/SNP-X master, CCM, or RTU (slave) protocol support. Requires PCM module for RTU master support. Communications LAN – Supports multidrop. Also supports Ethernet, FIP, Profibus, GBC, GCM, and GCM+ option modules. Override Yes Battery Backed Clock Yes Interrupts Supports the periodic subroutine feature. Type of Memory Storage RAM and Flash PCM/CCM Compatibility Yes Floating Point Math Support Yes, firmware-based in firmware releases 9.0 and later. . CPU 350 PORT ON OFF PS Important Product Information 7 GFK-1512N IC693CPU360 Data CPU Type Single slot CPU module Total Baseplates per System 8 (CPU baseplate + 7 expansion and/or remote) Load Required from Power Supply 670 milliamps from +5 VDC supply Processor Speed 25 MegaHertz Processor Type 80386EX Typical Scan Rate 0.22 milliseconds per 1K of logic (Boolean contacts) User Program Memory (maximum) 240K (245,760) Bytes. Note: Actual size of available user program memory depends on the amounts configured for the %R, %AI, and %AQ configurable word memory types (described below). Discrete Input Points - %I 2,048 Discrete Output Points - %Q 2,048 Discrete Global Memory - %G 1,280 bits Internal Coils - %M 4,096 bits Output (Temporary) Coils - %T 256 bits System Status References - %S 128 bits (%S, %SA, %SB, %SC - 32 bits each) Register Memory - %R Configurable in 128 word increments, from 128 to 16,384 words with DOS programmer, and from 128 to 32,640 words with Windows programmer Ver. 2.2 or VersaPro version 1.0. Analog Inputs - %AI Configurable in 128 word increments, from 128 to 8,192 words with DOS programmer, and from 128 to 32,640 words with Windows programmer Ver 2.2 or VersaPro version 1.0. Analog Outputs - %AQ Configurable in 128 word increments, from 128 to 8,192 words with DOS programmer, and from 128 to 32,640 words with Windows programmer Ver. 2.2 or VersaPro version 1.0. System Registers (for reference table viewing only; cannot be referenced in user logic program) 28 words (%SR) Timers/Counters >2,000 Shift Registers Yes Built-in Serial Port(s) 1 (uses connector on PLC power supply). Supports SNP, SNP-X slave protocols. Requires CMM module for SNP/SNP-X master, CCM, or RTU (slave) protocol support. Requires PCM module for RTU master support. Communications LAN – Supports multidrop. Also supports Ethernet, FIP, Profibus, GBC, GCM, and GCM+ option modules. Override Yes Battery Backed Clock Yes Interrupts Supports the periodic subroutine feature. Type of Memory Storage RAM and Flash PCM/CCM Compatibility Yes Floating Point Math Support Yes, firmware-based in firmware release 9.0 and later. CPU 360 PORT ON OFF PS 8 Important Product Information GFK-1512N IC693CPU363 Data CPU Type Single slot CPU module Total Baseplates per System 8 (CPU baseplate + 7 expansion and/or remote) Load Required from Power Supply 890 milliamps from +5 VDC supply Processor Speed 25 MegaHertz Processor Type 80386EX Typical Scan Rate .22 milliseconds per 1K of logic (Boolean contacts) User Memory (total) 240K (245,760) Bytes. Note: Actual size of available user program memory depends on the amounts configured for the %R, %AI, and %AQ configurable word memory types (described below). Discrete Input Points - %I 2,048 Discrete Output Points - %Q 2,048 Discrete Global Memory - %G 1,280 bits Internal Coils - %M 4,096 bits Output (Temporary) Coils - %T 256 bits System Status References - %S 128 bits (%S, %SA, %SB, %SC - 32 bits each) Register Memory - %R Configurable in 128 word increments, from 128 to 16,384 words with DOS programmer, and from 128 to 32,640 words with Windows programmer Ver. 2.2 or later, or VersaPro version 1.0 or later. Analog Inputs - %AI Configurable in 128 word increments, from 128 to 8,192 words with DOS programmer, and from 128 to 32,640 words with Windows programmer Ver 2.2 or later, or VersaPro version 1.0 or later. Analog Outputs - %AQ Configurable in 128 word increments, from 128 to 8,192 words with DOS programmer, and from 128 to 32,640 words with Windows programmer Ver. 2.2 or later, or VersaPro version 1.0 or later. System Registers (for reference table viewing only; cannot be referenced in user logic program) 28 words (%SR) Timers/Counters >2,000 (depends on available user memory) Shift Registers Yes Built-in Serial Ports 3 (one uses connector on PLC power supply). Supports SNP/SNPX slave (on all three ports) and RTU slave and Serial I/O (on Ports 1 and 2). Requires CMM module for CCM and PCM module for RTU master. Communications LAN – Supports multidrop. Also supports Ethernet, FIP, Profibus, GBC, GCM, and GCM+ option modules. Override Yes Battery Backed Clock Yes Interrupt Support Supports the periodic subroutine feature. Type of Memory Storage RAM and Flash PCM/CCM Compatibility Yes Floating Point Math Support Yes, firmware-based

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248