  • Description: GE Fanuc Series 90-30 Processor 80K Bytes User Memory 10K Registers
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU341 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -BB, -CC, -CD, -CE, -DE,

Product Manual Excerpt

Module Features Module features include: D Up to 12 positive logic (source) inputs with input voltage range selection of either 5 VDC (TTL) or 10 to 30 VDC (non-TTL). D Up to eight positive logic (source) outputs (four outputs with 1 amp rating, four configurable outputs with 0.5 amp rating) D Outputs protected by replaceable fuse (one fuse common to all outputs) D Dedicated processor provides 500 μ s I/O update D Counts per Timebase register for input rate measurement D Total Counts register (32-bit) accumulates total counts received by module D Four Strobe data registers for input position capture D Two Timer data registers for indicating input pulse length or input spacing in milliseconds D Thirty-two range comparators (outputs returned in %I and %AI data) D Software configuration D Internal module diagnostics D Individual LEDs that indicate Module OK and Configured OK status D Individual LEDs that indicate state of Outputs 1–4 D A removable terminal board for connection of field wiring Inputs can be used as count signals or edge-sensitive strobe signals. Outputs can be used to drive indicating lights, solenoids, relays, and other devices. Power to operate the module’s logic circuitry is obtained from the baseplate backplane’s 5 VDC bus. Power sources for the input and output devices must be supplied by the user or by the +24 VDC isolated output of the Model 30 power supply. The I/O Processor module provides a selectable threshold voltage to allow the inputs to respond to either a 5 VDC signal level or a 10 to 30 VDC signal level. The threshold is selected by configuration. All configuration parameters for the module are downloaded from the PLC to the I/O Processor after it passes its internal diagnostics. Once the module has been successfully configured, the CONFIG OK LED will turn on. Configuration parameters can be changed using Logicmaster configuration software or the Hand-held Programmer. Operation of the IOP module is monitored by a watchdog timer circuit. If the watchdog timer detects a module failure, it will force all outputs off and turn off the MODULE OK LED

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248