IC693CPU341 | IC693CPU341Q

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU341 | IC693CPU341Q

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 8 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 Processor 80K Bytes User Memory 10K Registers
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU341 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -BB, -CC, -CD, -CE, -DE,

Product Manual Excerpt

In TIMER mode, the comparator output turns ON when the ON PRESET is reached. The output stays ON until TIMER1 has elapsed. The output turns ON again when the OFF PRESET is reached. The output stays ON until TIMER2 has elapsed. By programming TIMER1 or TIMER2 to zero, only one output pulse per revolution will be produced. Example: If Output 1 has been configured for TIMER MODE, Output 1 will turn ON when the encoder value reaches 80. The output will stay ON until the Timer 1 value (in ms) has elapsed. Output 1 will turn ON again when the encoder value reaches 106. The output will stay ON until the Timer 2 value (in ms) has elapsed. ON PRESET = 80 OUTPUT 1 OUTPUT 1 PRESETS a45369 OFF PRESET = 106 TIMER 1 TIMER 2 ON/OFF Presets and Timer values can be set using Logicmaster Configuration software, the Hand-held Programmer or %AQ PLC data commands. Hardware 1–8 Output States in STOP Mode When the PLC is in the STOP mode, hardware Outputs 1–8 operate as follows with the different Output Default configurations: Out Default = NORMAL Outputs continue operating as normal, and if the en- coder continues to rotate will switch on and off at the configured preset points. Out Default = FORCE OFF Outputs switch off and remain off under all condi- tions in the PLC Stop mode. Out Default = HOLD LAST Outputs remain in the same state they were in before the PLC switch to STOP mode, regardless of the count inputs and the preset point states. Range Comparators 9–16 Range Comparators 9–16 control eight %I status bits using one ON preset and one OFF preset per bit. The bits are internally updated every 4 ms and reported to the PLC on each I/O scan. The ON/OFF preset pairs can be set using Logicmaster Configuration software, the Hand-held Programmer, or %AQ PLC data commands. 1 1-9 GFK-1028 Chapter 1 Introduction Range Comparators 17–32 Range Comparators 17–32 control 16 additional status bits using one ON preset and one OFF preset per bit. The bits are internally updated every 4 ms. The ON/OFF preset pairs can be set using Logicmaster Configuration software, the Hand-held Programmer, or %AQ PLC data commands. Range Comparator outputs 17–32 are reported to the PLC on each I/O scan using a %AI data word. Within the PLC, the %AI word can be copied directly to %Q memory to control a discrete output module. The %AI word can also be copied to %T or %M memory to facilitate additional bit oriented operations.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248