IC693CPU341 | IC693CPU341B

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU341 | IC693CPU341B

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 8 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 Processor 80K Bytes User Memory 10K Registers
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU341 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -BB, -CC, -CD, -CE, -DE,

Product Manual Excerpt

Wiring connections to and from user-supplied input and output field devices are made to the detachable terminal board supplied with each I/O module. This removable terminal board makes it easy to pre-wire field wiring to the user-supplied input and output devices, and to replace modules in the field without disturbing existing field wiring. The I/O terminal boards has 20 screw terminals. Each terminal accepts up to one AWG #14 wire using ring or lug type terminals. Minimum recommended wire size is AWG #22. These terminals require a flat or Phillips head screwdriver for installing field wiring. An isolated 24 volt DC supply is available on the power supply. Wires are routed to and from the terminals out of the bottom of the terminal board cavity. Installing a Terminal Board To install a terminal board with no wires attached: 1. Hook the hinge, located on the bottom of the terminal board, to the lower slot on the module. 2. Push the terminal board toward the module until it snaps into place. 3. Open the terminal board cover and ensure that the latch on the module is securely holding the terminal board in place. Caution Check the label on the hinged door and the label on the module to ensure that they match. If a wired terminal board is installed on the wrong module type, damage to the module could occur. When installing a terminal board that has wiring attached, verify that the terminal board is connected to the proper module type. Figure 2-3 shows the recommended procedure for terminal board installation. a43062 2 3 1 Figure 2-3. Installing a Terminal Board

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248