IC693CPU331 | IC693CPU331M

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU331 | IC693CPU331M

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 6 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 CPU 16K Bytes with Battery Included
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU331 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -BB, -CC, -CD, -CE, -LU, -UX,

Product Manual Excerpt

Latched Strobe Input Function Any of the four hardware inputs (9–12) not used by an Encoder provides a latched strobe input function (Figure 1-3). These inputs are shared with the four configurable hardware outputs controlled by range comparators 5–8. In addition to the functions described below, the status of each input 9–12 is reported as a %I bit. The rising or falling edge (configurable) of each input latches the latest encoder position as a strobe value (reported via %AI data) and sets a %I strobe status bit. The strobe latch %I bit is reset by a corresponding %Q bit controlled by the PLC. Once the strobe data is latched, another strobe input will not change the data until the %I strobe status bit is reset. A configuration option allows range comparator 5–8 outputs to be used as additional enable bits for the latched strobe functions. Range comparator 5 can be configured to enable the input 9 strobe latch. Range comparator 6 can be configured to enable the input 10 strobe latch, etc. Time Measurement Function The input time measurement function (Figure 1-3) provides two timers using input pairs 9–10 and 11–12. Each timer can be configured to operate in two modes: Single Input Timer Operation (default mode) One edge of the second input (10 or 12) of each pair starts a timer with 1 ms resolution. The opposite edge of the same input halts the timer. The timer value is reported to the PLC using one word of %AI data for each timer. The input edge configured to set the strobe latch for inputs 10 or 12 is also used to start the associated timer. Dual Input Timer Operation The second input (10 or 12) of each pair starts a timer with 1 ms resolution. The first input (9 or 11) of each pair halts the timer. The timer value is reported to the PLC using one word of %AI data for each timer. The input edge configured to set the strobe latch for each input is also used to start/stop the associated timer.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248