IC693CPU323 | IC693CPU323V

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU323 | IC693CPU323V

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc 10-Slot Rack With Turbo CPU in base 12K bytes User
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU323 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AE,

Product Manual Excerpt

January 2010 GFK-0702AC I MPORTANT P RODUCT I NFORMATION READ THIS INFORMATION FIRST Product: IC693 CPU Firmware Release 8.40 IC693CPU311-AD, AE IC693CPU313-U, V IC693CPU323-U, V IC693CPU331-CE IC693CPU341-W Introduction This document contains information that is not available in any other publication; therefore, we recommend you save it for future reference. This document discusses a new feature released in firmware version 8.40 for the five CPU modules listed above, and also contains information on previous release 8.21. This document is revised to correct an error in the previous version (AB), which stated that firmware version 8.21 supports the DSM314 motion module. IC693 CPUs with firmware version earlier than 10.0 do not support DSM314. New Features and Functionality of Firmware Release 8.40 Firmware release 8.40 adds the Ignore Fatal Fault feature to the five CPUs listed above. This feature is enabled/disabled with a new configuration parameter. When set to Enabled, the CPU will ignore, during power-up, any active PLC error mode condition. If enabled, this feature also requires the Power-up Mode parameter be set to Run or Last. If this feature is enabled, and a running CPU goes into Stop/Fault mode, the CPU can be started back up in Run mode by power-cycling the PLC. (Previously, it was necessary to use programming software or a Hand-Held Programmer to restart a CPU that had gone into Stop/Fault mode.) When it powers back up, the CPU will ignore the current error mode condition and proceed to the previous operating mode (Run/Stop). This parameter has no effect on the detection and logging of faults. The default setting for this parameter is Disabled. This feature is useful in applications where the PLC experiences a nuisance fault, such as due to noise from a nearby electrical storm, and no support person is on-site to restart it; however, there may be applications where it is not safe to use this feature, so read the warning below. To configure this feature, you must use CIMPLICITY Machine Edition software, VersaPro 1.1 or later, or the MS DOS  -based programming software, version 9.03 or later. This feature is not supported in the Hand- Held Programmer. Users with earlier versions of these CPUs who would like to use this new feature may upgrade these earlier CPUs to firmware release 8.40 (see the heading “Firmware Upgrade Kits”). Warning The Ignore Fatal Fault feature should not be used (should be set to Disabled ) in applications where a restart under fault conditions could produce an unsafe condition in the controlled equipment. It is the responsibility of the system designers to determine whether this feature can be used safely with their equipment. Failure to follow this warning could result in injury or death to personnel and/or damage to equipment.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248