IC693CPU323 | IC693CPU323H

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU323 | IC693CPU323H

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc 10-Slot Rack With Turbo CPU in base 12K bytes User
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU323 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AE,

Product Manual Excerpt

Configured Constant Sweep Setting Parameter If the configured constant sweep mode is enabled in the PLC, the sweep time value must also be selected. The configured constant sweep setting parameter can be overridden by the active constant sweep setting parameter during RUN mode, but upon going from STOP to RUN mode, the configured constant sweep setting parameter value is copied to the ac- tive constant sweep setting parameter. This allows the user to maintain a configured set- ting, while fine tuning the setting during RUN mode with the active constant sweep setting parameter. If the configured constant sweep mode is disabled, this parameter is ignored. The configured constant sweep value may range between 5 and 200 milliseconds, inclusive. Use the Right cursor key to scroll through the PLC parameters until the configured constant sweep setting (CFG CONS TM) parameter is displayed. To set the sweep time, enter a val- ue between 5 and 200 milliseconds, inclusive, and press the ENT key. The default setting is 100 milliseconds. 3. SVCREQ #26: Interrogate I/O Use SVCREQ function #26 to interrogate the actual modules present and compare them with the rack/ slot configuration, generating addition, loss, and mismatch alarms, as if a store configuration had been performed. This SVCREQ will generate faults on both the PLC and I/ O fault table, depending on the fault. This function has no parameter block and always outputs power flow. NOTE: The time for this SVCREQ to execute depends on how many faults exist. Therefore, execution time of this SVCREQ will be greater for situations where more modules are faulted. Example: In the following example, when input %I0251 is ON the actual modules are interrogated and compared to the rack/ slot configuration. Output %Q0001 is turned on after the SVCREQ is complete

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248