IC693CPU323 | IC693CPU323G

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU323 | IC693CPU323G

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc 10-Slot Rack With Turbo CPU in base 12K bytes User
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU323 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AE,

Product Manual Excerpt

2. ACTIVE AND CONSTANT SWEEP MODES Two new CPU parameters have been added after ”Power-Up Mode”: Parameter Selections Default Value Active Constant Sweep Mode DISABLE DISABLE ENABLE Active Constant Sweep Setting 5 - 200 msec 100 msec In addition, the ”Constant Sweep Mode” and ”Constant Sweep Setting” parameters have been renamed to ”Configured Constant Sweep Mode” and ”Configured Constant Sweep Setting”. Active Constant Sweep Mode Parameter The PLC may be configured during RUN mode to use a constant amount of time per sweep. The active constant sweep mode parameter allows the user the ability to enable or disable the constant sweep mode while the program is running, and have the affects not- iced immediately. This parameter can be used to toggle the sweep mode of the PLC, with- out changing the configured constant sweep mode parameter. The active constant sweep mode parameter, once changed, is only valid during the current RUN mode. Upon going from STOP to RUN mode, the configured sweep mode parameter value is copied to the active sweep mode parameter. Use the Right cursor key to scroll through the PLC parameters until the active constant sweep mode (ACT CNSW) parameter is displayed. Then, use the -/ + key to toggle the selection between DISABLE and ENABLE. By default, the PLC will execute every sweep as fast as possible. Active Constant Sweep Setting Parameter If the constant sweep mode is enabled in the PLC during RUN mode, then the Active Constant Sweep Setting Parameter can be used to adjust the sweep time. This allows the user to fine tune the sweep time while the PLC is running a program. Changing this pa- rameter does not affect the configured constant sweep setting parameter. The active constant sweep setting is only valid during the current RUN mode, as long as Active Constant Sweep Mode is enabled. Upon going from STOP to RUN mode, the configured sweep setting parameter value is copied to the active sweep setting parameter. If the active constant sweep mode is disabled, this parameter is ignored. The active constant sweep val- ue may range between 5 and 200 milliseconds, inclusive. Use the Right cursor key to scroll through the PLC parameters until the active constant sweep setting (ACT CONS TM) parameter is displayed. To set the active sweep time, enter a value between 5 and 200 milliseconds, inclusive, and press the ENT key. The default set- ting is 100 milliseconds. Configured Sweep Mode Parameter The PLC may be configured to use a constant amount of time per sweep. The constant sweep mode parameter should be enabled when I/ O points or register values must be polled at a constant frequency, as in control algorithms. The configured sweep mode pa- rameter can be overridden by the active constant sweep mode parameter during RUN mode, but upon going from STOP to RUN mode, the configured sweep mode parameter 9 Important Product Information GFK-0702G value is copied to the active constant sweep mode parameter (see Active Constant Sweep Mode Parameter). The configured sweep mode parameter can only be edited during STOP mode. Use the Right cursor key to scroll through the PLC parameters until the configured constant sweep mode (CFG CNSW) parameter is displayed. Then, use the -/ + key to toggle the selection between DISABLE and ENABLE. By default, the PLC will execute every sweep as fast as possible

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248