IC693CPU311 | IC693CPU311Z

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU311 | IC693CPU311Z

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 5-Slot Rack With CPU in base
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU311 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AD, -AE,

Product Manual Excerpt

4 Series 90-30 I/O Processor User’s Manual - June 1994 GFK-1028 4-4 Indicates the total input counts received by the IOP. This total counts register can be initialized (preloaded) by a %AQ data command from the PLC. It is initialized to 0 at power-up. For AQUADB selection, it is also initialized to 0 at the Home position marker. In AQUADB mode, the Preload Input does not affect Total Counts. Returns the captured input Binary data value recorded when the strobe input occurred. Inputs 9–12 correspond to Strobe inputs 1–4, respectively. Either input edge may be configured to trigger the strobe data capture. Indicates the time (in ms) between the input edges of Input 10 (default configuration) or the input edges of Inputs 9–10 depending upon the configuration. To start the capture of this timing data, the strobe latch for Input 10 must be cleared, and if the strobe 2 enable configuration is RCOMP-6, the output range comparator 6 must be on when the Input 10 strobe occurs. If Input 9 is used to stop the time measurement and the strobe 1 enable configuration is RCOMP-5, output range comparator 5 must be on (when strobe input occurs) before the timing will stop. Indicates the time (in ms) between the input edges of Input 12 (default configuration) or the input edges of Inputs 11–12 depending upon the configuration. To start the capture of this timing data the strobe latch for Input 12 must be cleared, and if the strobe 4 enable configuration is RCOMP-8, output range comparator 8 must be on when the Input 12 strobe occurs. If Input 11 is used to stop the time measurement and the strobe 3 enable configuration is RCOMP-7, output range comparator 7 must be on (when strobe input occurs) before the timing will stop. Indicates the ON/OFF state for range comparator outputs 17–32 based solely on the ON and OFF presets defined for each output.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248