GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU311 | IC693CPU311Y

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 5-Slot Rack With CPU in base
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU311 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AD, -AE,

Product Manual Excerpt

%AI Data Words The following %AI Data words are transferred automatically from the IOP to the CPU each sweep. The actual address of each data word depends on the starting address configured for the %AI references when the IOP module was configured (see Section 3 for these configuration details). The word numbers listed in the following table are offsets from this %AI reference address. Word * Description 000 Module Status Code 001 Counts per timebase 002 Gray Code Encoder Data ♦ 003 Binary Data 004–005 Total Counts 006 Strobe Data 1 (Input 9) 007 Strobe Data 2 (Input 10) 008 Strobe Data 3 (Input 11) 009 Strobe Data 4 (Input 12) 010 Start/Stop Timer 1 Data 011 Start/Stop Timer 1 Data 012 Range Comparator 17–32 status (16 bits) 013 reserved 014 reserved * Word numbers listed in table are offsets from the starting address for %AI References. ♦ Not applicable for the AQUADB function selection. %AI Data Word Descriptions Indicates the Error identification code when an error is detected by the IOP. The error identified is the first error encountered and the error condition must be cleared before following errors will be reported. Refer to Appendix A for a listing and explanation of these codes. Indicates the number of input counts received in the last time interval defined by the Timebase configuration parameter. With the default Timebase (1000 ms), this indicates counts per second. Indicates the Gray code value presently being received by the IOP inputs from the Encoder parallel outputs. Indicates the Binary code equivalent of the Gray code value being received by the IOP inputs from the Encoder parallel outputs, or the input counter Binary count value for the AQUADB selection

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248