IC693CPU311 | IC693CPU311X

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU311 | IC693CPU311X

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 5-Slot Rack With CPU in base
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU311 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AD, -AE,

Product Manual Excerpt

%I Status Bit Descriptions Indicates the ON/OFF state for range comparator outputs 1–8. If the Output Mode = Preset, the state of the status bit is defined by the ON/OFF presets. If the Output Mode = Timer, the status bit will be on after each preset point is passed for the length of time designated by Timer 1 or Timer 2. These bits always indicate the output state for range comparators 1–8, even if the corresponding hardware output is disabled (and Terminal Points 9–12 are used as Inputs). Indicates the ON/OFF state for range comparator outputs 9–16 based solely on the ON & OFF presets defined for each output. Indicates the present on/off input status for Inputs 9–12. State changes in these inputs produce strobe inputs 1–4 according to the configured strobe edge (input 9 = strobe 1, input 10 = strobe 2, etc.). Indicates strobe data has been captured by Inputs 9–12, respectively. Once acknowledged by the PLC ladder program, the corresponding %Q command (Reset Strobe) should be sent to clear the strobe status for future strobe captures. Following strobes will be locked out until this flag is cleared . Indicates the Home marker, after a Home command sequence, has been recognized and the AQUADB Input Counter has been set to the Home preload value. This status flag indicates to the PLC that the AQUADB input counter has been preloaded by the faceplate Preload Input. When acknowledged, this status indication should be cleared (by the Reset Preload Latch %Q bit) in order to recognize the occurrence of future preloads. This latch locks out the effect of the faceplate Preload Input, it will not be effective again until this flag is cleared. This latch does not apply to the %Q preload command bit. This %I bit reports the status of the faceplate Home switch input. When this switch is closed during the Home cycle, the next encoder marker encountered will preload the counter with the configured Home value and set the Home Found %I indication. If a Home Switch is not used, this %I bit can be used as a general purpose PLC input reporting the status of faceplate Input 5. These three %I bits indicate the on/off status of Inputs 6, 7, & 8 thus making these inputs available to the PLC ladder for general purpose control functions. Indicates the module power-up tests have all passed and the IOP module is ready for operation. Indicates an error condition has been detected by the IOP and the error code is reported in the module status code word of the first %AI word. If the error was caused by a bad data command (such as a %AQ data command), the data has been ignored. Once acknowledged by the PLC ladder program, the %Q command (Clear error) must be toggled to clear the error status

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248