IC693CPU311 | IC693CPU311V

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU311 | IC693CPU311V

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 5-Slot Rack With CPU in base
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU311 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AD, -AE,

Product Manual Excerpt

Note All screen entries not described here are identical to those described for the ABS Encoder (Figure 3-1) Selects the Input filter range for both AQUADB Count inputs , the Marker input, and the Preload input. If the maximum count input rate is < 25 khz, use the 20 μ s default selection, otherwise use the 2 μ s selection. Default: 20 μ s This entry establishes the count range for the internal counter registering the AQUADB input counts. It counts from 0 to this maximum value and then rolls over to 0. The range for this parameter is 10 to 64,999 counts. Default: 255 This configures the initializing count value to be set into the input counter when the preload command is received by the I/O Processor. The preload command can be from either the preload faceplate input or the %Q bit command. Range: 0 to maximum counts This configures the initializing count value to be set into the input counter when the Marker input is received by the I/O Processor when executing the Home cycle. Range: 0 to maximum counts Inp Filter Max Counts Preld Posn Home Posn 3 3-14 GFK-1028 Series 90-30 I/O Processor User’s Manual - June 1994 Configuration Screen 2, ABS or AQUADB Encoder Function Catalog #: IO PROCESSOR MODULE SLOT IOP ON Preset : 255 OFF Preset : 0 RANGE COMPARATORS 01–04 Timer 1 ms : 0 01 MODE: PRESET ON Preset : 255 OFF Preset : 0 Timer 1 ms : 0 02 MODE: PRESET ON Preset : 255 OFF Preset : 0 Timer 1 ms : 0 03 MODE: PRESET ON Preset : 255 OFF Preset : 0 Timer 1 ms : 0 04 MODE: PRESET Timer 2 ms : 0 Timer 2 ms : 0 Timer 2 ms : 0 Timer 2 ms : 0 Figure 3-3. IOP Configuration Screen 2 (Function = ABS or AQUADB Encoder) This entry allows you to designate the type of pulse generated by the range comparator output. The PRESET selection causes the output to be ON (or OFF) continuously from one preset point to the other. The TIMER selection causes timed pulses to be produced at the preset points as defined by Timer 1 and Timer 2. Default: PRESET This parameter specifies the count input value that causes the output to turn ON. The value can be anything within the count range. Default: Maximum encoder value for Absolute Encoders, 255 for AQUADB mode This parameter specifies the count input value that causes the output to turn OFF. The value can be anything within the count range. Default: 0 This parameter is effective only when the output mode is TIMER. It specifies the length of the pulse (in milliseconds) that is produced by the output when the input count reaches the ON preset value. A value of 0 specifies no output pulse at the ON preset point. Default: 0 This parameter is effective only when the output mode is TIMER. It specifies the length of the pulse (in milliseconds) that is produced by the output when the input count reaches the OFF preset value. A value of 0 specifies no output pulse at the OFF preset point. Default: 0 Note These parameters are repeated for outputs 2–4 on this screen. The next screen displayed by the configuration software (Screen 3) provides entry of the same parameters for Range Comparator Outputs 5–8. Because Screens 2 and 3 are similar in appearance, Screen 3 is not shown here.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248