IC693CPU311 | IC693CPU311U

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU311 | IC693CPU311U

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 5-Slot Rack With CPU in base
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU311 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AD, -AE,

Product Manual Excerpt

3 3-12 GFK-1028 Series 90-30 I/O Processor User’s Manual - June 1994 This parameter allows you to select whether Terminal point 11 is to be used for an output or an input. DISABLED defines the point as Input 11 while ENABLED selects it for use as output #7. Default: DISABLED This parameter allows you to select whether Terminal point 12 is to be used for an output or an input. DISABLED defines the point as Input #12 while ENABLED selects it for use as output #8. Default: DISABLED This parameter selects the state the hardware outputs will assume if the PLC is stopped. NORMAL indicates that the outputs continue to operate under control of the input counts to the I/O Processor. FRCOFF causes the outputs to be forced off if the PLC stops. HOLD causes the I/O Processor to retain the last state of the outputs before the PLC stopped. Default: NORMAL This parameter configures the strobe 1 (Input 9) trigger edge for positive (rising) or negative (falling). Default: POS This parameter configures the strobe 2 (Input 10) trigger edge for positive (rising) or negative (falling). Default: POS This parameter configures the strobe 3 (Input 11) trigger edge for positive (rising) or negative (falling). Default: POS This parameter configures the strobe 4 (Input 12) trigger edge for positive (rising) or negative (falling). Default: POS This parameter allows you to select whether strobe 1 (Input 9) is ALWAYS enabled (default selection) or is ONLY enabled when preset output 5 is ON (RCOMP-5 selection). Default: ALWAYS This parameter allows you to select whether strobe 2 (Input 10) is ALWAYS enabled (default selection) or is ONLY enabled when preset output 6 is ON (RCOMP-6 selection). Default: ALWAYS This parameter allows you to select whether strobe 3 (Input 11) is ALWAYS enabled (default selection) or is ONLY enabled when preset output 7 is ON (RCOMP-7 selection). Default: ALWAYS This parameter allows you to select whether strobe 4 (Input 12) is ALWAYS enabled (default selection) or is ONLY enabled when preset output 8 is ON (RCOMP-8 selection). Default: ALWAYS

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248