IC693CPU311 | IC693CPU311-AA

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CPU311 | IC693CPU311-AA

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 5-Slot Rack With CPU in base
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CPU311 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -AB, -AC, -AD, -AE,

Product Manual Excerpt

%Q Control Bits The following %Q Control Bits are transferred automatically from the CPU to the IOP each sweep. The actual addresses of the Control Bits depend on the starting address configured for the %Q references (see Section 3 for these configuration details). The bit numbers listed in the following table are offsets from this %Q reference address. Bit* Description Bit* Description 00 Enable Output 1 16 reserved 01 Enable Output 2 17 reserved 02 Enable Output 3 18 reserved 03 Enable Output 4 19 reserved 04 Enable Output 5 (only if cfg = enabled) 20 Reset Strobe 1 (Input 9 latch) 05 Enable Output 6 (only if cfg = enabled) 21 Reset Strobe 2 (Input 10 latch) 06 Enable Output 7 (only if cfg = enabled) 22 Reset Strobe 3 (Input 11 latch) 07 Enable Output 8 (only if cfg = enabled) 23 Reset Strobe 4 (Input 12 latch) 08 reserved 24 Home Command ♦ 09 reserved 25 Reset Preload Latch ♦ 10 reserved 26 Preload Command ♦ 11 reserved 27 reserved 12 reserved 28 reserved 13 reserved 29 reserved 14 reserved 30 reserved 15 reserved 31 Clear Error * Bit numbers are offsets from the starting address for %Q References. ♦ Applies to AQUADB function only. %Q Control Bit Descriptions Enables each hardware Output (ON = Enable). If the configuration for Outputs 5–8 are DISABLED, then these corresponding output bit commands have no effect. This command clears the respective strobe latch condition so the next strobe can be captured and reported via the corresponding %I bits. If this %Q bit is held ON, the %I status bit will stay OFF and every strobe input pulse will cause new strobe data to be captured in the associated %AI strobe register. This initiates the Home command sequence. When the Home Marker Input is recognized, the input counter will be preloaded with the configured home value, and the Home Found %I indication will be set. This command clears the Preload Latch status after it has been set by the Preload switch Input. If this command is left on, it will allow all Preload switch inputs to be effective. This command preloads the input counter with the configured preload value. The Preload Latch status %I indication will not be set by this command since it only applies to the Preload faceplate input.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248