IC693CMM321 | IC693CMM321-KN

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CMM321 | IC693CMM321-KN

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 Modbus EGD Ethernet Interface TCP/IP Module
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CMM321 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -KN, -KM, -KL, -JL, -JK, -HJ, -GH, -FG, -EF, -EE, -DD, -CD, -CC, -BA,

Product Manual Excerpt

December 2012 GFK - 1085X I MPORTANT P RODUCT I NFORMATION READ THIS INFORMATION FIRST Product: Factory LAN TCP/IP Ethernet Interface Module for Series 90 - 30 PLC IC693CMM321 - K N with Firmware Release 3. 20 Ethernet Firmware version 3.20 addresses product security issues identified in Security Advis ory document KB15240 ( http://support.ge - ip.com/support/index?page=kbchannel&id=S:KB15240 ). GE Intelligent Platforms strongly recommends that you update to firmware version 3.20 to protect your system from these issues. Important Note: Until the Station Manager password has been changed to a value other than “system , ” the password vulnerabilities will remain exploitable via the serial Station Manager and all access to Modify - level commands will be disabled on the Ethernet remote Station Manager . This module provides MODBUS/TCP Master and Slave functionality. It provides network communications using the SRTP (Service Request Transfer Protocol) over standard TCP/IP (Transmissio n Control Protocol / Internet Protocol) on an Ethernet Local Area Network (LAN). The Ethernet Interface supports communication between Series 90 PLCs and PACSystems Rx7i controllers equipped with TCP/IP Ethernet Interfaces, and VersaMax PLCs equipped with EBI001 modules. Documentation For changes and additions to user documentation, see page 8 . TCP/IP Ethernet Communications User’s Manual, GFK - 1541 version B or later TCP/IP Ethernet Communications Station Manager Manual, GFK - 11 86 version G or later Release History Part Number Firmware Version Date Comments IC693CMM321 - KN 3.20 Dec. 2012 Addresses product security issues identified in Security Advisory document KB1 5240 ( http://support.ge - ip.com/support/index?page=kbchannel&id=S:KB1 5240 ). IC693CMM321 - KM 3.14 Oct. 2010 Resolves intermittent failure of Modbus/TCP port to respond to Modbus/TCP Client requests. IC693CMM321 - KL 3.13 Mar. 2010 Hardware u pdate to remove AAUI port. IC693CMM321 - JL 3.13 Nov. 2009 See GFK - 1085U for problem resolved. IC693CMM321 - JK 3.12 Jan. 2008 See GFK - 1085T for problem resolved. IC693CMM321 - HJ 3.11 Jan. 2005 See GFK - 1085S for problems resolved. IC693CMM321 - GH 3.10 Ma r. 2003 Adds MODBUS/TCP COMMREQ operations for Master and Slave; Corrects problem with interruption of Ethernet transmission. IC693CMM321 - GH 3.10 Jul. 2002 MODBUS/TCP Master and Slave functionality for modules with catalog numbers IC693CMM321 - Fx. IC6 93CMM321 - FG 3.00 Nov. 2001 Full duplex capability; 10Base - T port. IC693CMM321 - EF 2.20 Nov. 1999 See GFK - 1085L for new features and problems resolved. IC693CMM321 - EE 2.10 Jul. 1997 See GFK - 1085K for new features and problems resolved. IC693CMM321 - DD 2.00 Dec. 1996 Hardware change. IC693CMM321 - CD 2.00 Oct. 1996 Adds support for Unsolicited Messages. IC693CMM321 - CC 1.11 Jun. 1996 See GFK - 1085E for new features and problems resolved. IC693CMM321 - AA/BA 1.00 Dec. 1995 Initial release. Version – BA adds CE Mark approval. 2 Important Product Information GFK - 1085X Release 3.20 Details Firmware Updates ■ Firmware releases numbered 3.00 and greater apply only to modules with hardware version - Fx or later. Users of IC693CMM321 - Ex and earlier modules can update by replacing their older Ethernet In terface module with a later module. ■ Hardware versions – Fx and later can be upgraded to hardware version - Kx by returning the module to the factory. Firmware Field Upgrade Kit The following field upgrade kit for firmware version 3.20 can be downloaded from the Support website at http://support.ge - ip.com . 44A751570 - G0 6 A Station Manager cable (IC693CBL316) is required to update the f irmware. Caution Do not attempt to upgrade your IC693CMM321 to release 3.14 or later unless your Series 90 - 30 PLC has a reliable power source. DO NOT turn power off during the upgrade process. Functional Compatibility Firmware release 3. 20 of the IC693CMM 321 is compatible with these products: ■ Series 90 - 30 PLC CPU firmware version 6.50 or later; restricted operation with CPU firmware 5.03 (6.03 for Model 351 CPU). See “Additional Restrictions with CPU Firmware Earlier than Version 6.50” on page 3 . ■ PLC Logic Developer version 2.11 or later. ■ VersaPro version 1.01 or later. Version 2.02 or later is required to store hardware configurations that contain module initialization files larger than 32,768 bytes. ■ Control programming softwar e, version 2.01 or later. ■ Logicmaster 90 - 30 programming software IC693 version 6.01 or later. ■ Logicmaster 90 - 30 TCP/IP Ethernet. Version 7.01 or later is required for Ethernet communication with the PLC. Problems Resolved by Firmware Release 3. 20 Addresses product security issues Firmware version 3.20 addresses product security issues identified as Security Advisory GEIP12 - 18 in Security Advisory document KB15240 ( http://support.ge - ip.com/support/index?page=kbchannel&id=S:KB15240) . Important Product Information 3 GFK - 1085X Restrictions and Open Issues ■ The Ethernet Interface sometimes generates multiple exception log events and PLC Fault Table entries when a single error condition occurs. Under repetitive e rror conditions, the exception log and/or PLC Fault Table can be completely filled with repetitive error messages. ■ Initialization errors that generate any of the following exception log events should also restart the Ethernet Interface into Maintenance sta te: event 1b, entry 2 = 0003h, event 1c, entry 2 = 25h, or event 1c, entry 2 = 26h. The Ethernet Interface does not restart in these conditions. ■ Use of the same IP Address by this Ethernet Interface and by another device on the same network results in the PLC Fault Table message “Bad remote application request; discarded request.” This condition should be identified more precisely. ■ When the client or server PLC scan time exceeds 100 ms, channels may fail with error codes 2411, 0B11, 9B90, 3F11, or 9590. T he error codes may be viewed by doing a Stat H command. ■ While a local Station Manager “TRACE LZ” troubleshooting command is in effect at an Ethernet Interface, do not issue Station Manager “REM TEST” commands to it from a remote Interface. Doing so can cause errant behavior, including Interface lockup and loss - of - module in the PLC fault table. ■ After performing a firmware update to an Ethernet Interface in which one or more Advanced User Parameters have been set to non - default values, the PLC Fault Ta ble does not contain the message it should (“LAN IF can’t init - check parms; running soft Sw Utl”); rather, no fault table entry appears. There is no indication in the fault table that the Ethernet Interface has entered Maintenance state to permit resetting of the user parameter(s). The Ethernet Interface does generate an entry in its exception log. ■ The TCP tallies CurEstab and EstabRes do not always report the correct value. ■ An Information Report channel may remain in the AWAIT_DRSP or AWAIT_CRSP state inde finitely if the remote host fails to send a response. ■ When using VersaPro via Ethernet through this Ethernet Interface, a Clear operation that does not include clear of Software Configuration causes VersaPro to stop responding. This behavior is not observe d using the other Ethernet programmers or if VersaPro is connected to the PLC via the Ethernet Interface within an IC693CPU364. Rebooting the VersaPro host PC is often required to re - establish communication with the PLC. Additional Restrictions with CPU Fi rmware Earlier Than Version 6.50 Ethernet Programming Not Supported Using a PLC programmer via Ethernet requires IC693 CPU version 6.5 or later. The programmer may appear to connect with a PLC using older CPU firmware, but essential functions will not work correctly. CAUTION Do not attempt to use an Ethernet programmer with CPU firmware earlier than version 6.50. Unpredictable operation of the PLC CPU and MS - DOS programming software will occur. Single Incoming Network Connection to CPU PLC CPU firmware ver sions earlier than 6.50 can support only one incoming network connection through the Ethernet Interface at a time. The Ethernet Interface consequently supports only one incoming connection at a time when used with this CPU firmware. 4 Important Product Information GFK - 1085X No Operation in Expansi on or Remote Rack With CPU firmware versions earlier than 6.50, locate the Ethernet Interface in the main PLC rack only (Rack 0, which contains the CPU). The Ethernet Interface is not supported by this CPU firmware in an expansion or remote PLC rack. Incom ing Network Connection May Be Refused After Restart After any restart, including power up, the Ethernet Interface is unable to accept incoming network connections for approximately 2.5 seconds after the LAN Interface OK bit of the LAN Interface Status Word is set. This occurs only with CPU firmware earlier than version 6.50. Unconfigured Ethernet Interface Inoperative for Two Minutes After Restart With CPU firmware versions earlier than 6.50, an unconfigured Ethernet Interface waits for two minutes after ea ch restart to receive valid configuration data from the PLC CPU. The interface slowly flashes its Module OK LED and is not operational during this time. This behavior occurs when a new interface is powered on for the first time. It also occurs when a PLC P rogrammer user clears the PLC configuration, or stores a new configuration with an empty slot or different module type at the location where the Ethernet Interface is installed

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248