IC693CMM321 | IC693CMM321-FG

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CMM321 | IC693CMM321-FG

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 Modbus EGD Ethernet Interface TCP/IP Module
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CMM321 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -KN, -KM, -KL, -JL, -JK, -HJ, -GH, -FG, -EF, -EE, -DD, -CD, -CC, -BA,

Product Manual Excerpt

IC693CMM321-FG, with FW version 3.00, Full duplex capability, 10Base-T port November 26, 2001 GFK-1085M I MPORTANT P RODUCT I NFORMATION READ THIS INFORMATION FIRST Product: Factory LAN TCP/IP Ethe rnet Interface Module for IC693 PLC IC693CMM321-FG with Firmware Release 3.00 Introduction This document contains information about this product that is not available in any other publication; therefore, we suggest you read it, then save it with your other PLC documentation. This document discusses details of the redesigned IC693CMM321-FG Ethernet Interface modul e, which provides a number of im provements over previous version IC693CMM321-EF, which it replaces. Version Compatibility The IC693CMM321 module was redesigned and released as IC693CMM321-FG in November 2001. The redesigned module has all of the functionality of the previous design pl us some additional features and problem corrections. The redesigned module may be used as a direct replacement for all earlier modules. General Description In general this module provides network communications using the SRTP (Service Request Transfer Protocol) over standard TCP/IP (Transmission Control Protocol / Internet Protocol) on an Ethernet Local Area Network (LAN). The Ethernet Interface supports communicati on between IC693 PLCs and/or IC697 PL Cs equipped with TCP/IP Ethernet Interfaces. It can communicate with the various Windows-ba sed PLC software products and the TCP/IP version of the DOS-based software. Hardware Identification for IC693CMM321-FG EM3A2-44A751166-G01 R00 Software Identificati on for IC693CMM321-FG • Software Loader: Version 3.00 • TCP/IP: Version 3.00 Replaces Module Versions: IC693CMM321- AE/BE/CE/DE/EE/EF Firmware Field Update Kit Since this is the initial release of the redesigned module (I C693CMM321-FG), ther e is no need for a firmware update kit. Note that the firmware for the redesigned module w ill not work in the previous versions (IC693CMM321-EF and 2 Important Product Information GFK-1085M earlier) of this module. Users of the IC693CMM321-EF and earlier modules can update to version 3.0 of the TCP/IP firmware only by replacing thei r older Ethernet Interface module with an IC693CMM321-FG module. Hardware Compatibility EM3A2-44A751166-G01 R00 or later versions. Functional Compatibility Release 3.00 of the IC693 Ethernet Inte rface is compatible with these products: • IC693 PLC CPU firmware version 6.50 or later; restricted operation with CPU firmware 5.03 (6.03 for Model 351 CPU). See the section Additional Restrictions W ith CPU Firmware Earlier Than Version 6.50. • PLC Logic Developer version 2.11 or later. • VersaPro Version 1.01 or later. Version 2.02 or later is required to store hardware configurations that contain module initialization files larg er than 32,768 bytes. • Windows ® -based programming software, Version 2.01 or later. • The MS-DOS ® -based programming software IC693 version 6.01 or later. • The MS-DOS-based programming software IC693 TCP/IP Ethernet version 7.01 or later. Documentation TCP/IP Ethernet Communications for the Series 90 PLC User’s Manual TCP/IP Ethernet Communications for the Series 90 PLC Station Manager Manual DEMKO Agency Approval Beginning with version EE, this module was granted DEMKO Agency approval and is labeled accordingly. Version Identification There are currently, two different designs of IC693CMM321 modules. The information in this table and in the next heading, Module Differences, will help you identify whethe r a particular module is a 10Base-T type or an AAUI-only type. Version* Description IC693CMM31-EF and earlier versions AAUI-only type IC693CMM321-FG and later versions 10Base-T type * The module’s version is indicated by the two lette rs at the end of the product catalog number. For example, in the catalog num ber IC693CMM321-AA, the versio n is indicated by AA. ® MS-DOS, Windows, and Microsoft are registered trademarks of Microsoft, Incorporated. Important Product Information 3 GFK-1085M Module Differences Item 10Base-T Module AAUI-Only Module Catalog number IC693CMM321-FG and later IC693CMM321-EF and earlier Firmware upgrade Uses the Statio n Manager port. Requires an IC693CBL316 cable. Uses the Software Loader Port. Requires an IC690ACC901 cable. 10Base-T port? Yes. An external transceiver is not required for 10Base-T networks. None. An external transceiver must be connected to the AAUI port. Full-duplex operation? Yes, but only on the 10Base-T port. Requires special configuration (half-duplex is the default). Auto-negotiation is not supported. * Not supported Third LED indicator (from top of module) FDX (full-duplex) SER (Serial) Access to AAUI port (on bottom of module) You do not have to remove the front cover to insert the cable. You must remove the front cover in order to insert the cable. Access to port connectors and Restart Pushbutton on front of module. You do not have to remove the front cover to access these items. You must remove the front cover to access these items. *When using full-duplex mode, a network device (hub, switch, router, etc.) conn ected to this modul e must be manually configured for full-duplex mode because the CMM321 does not support duplex m ode auto-negotiation. See the Full-Duplex Capability item and warning note in the section New Features and F unctionality of this Release (3.00) for additional details. OK LAN FDX STAT CMM321 ETHERNET INTERFACE 10BASE-T STATION MGR RS-232 ETHERNET RESTART CMM 321 ETHERNET INTERFACE OK LAN SER STAT 10Base-T Type Module (Ports and Restart pushbutton accessible without removing cover). AAUI-Only Type Module (Ports and Restart pushbutton behind cover) AAUI Restart Pushbutton Station Manager Port Firmware Upgrade Port AAUI Port AAUI Port 4 Important Product Information GFK-1085M Special Operating Notes This Firmware Release Is Incompatible With Version IC693CMM321-EF or Older Hardware You should not attempt to use this firmware with older versions of this module. If this firmware version were to be loaded to an IC693CMM321-EF or older vers ion of this module, the module will not function as expected, and the following symptoms will be observed: 1. The interface is unable to go online. 2. The STAT and SER LEDs blink alternately at a ½-second rate. 3. The LAN Interface OK and LAN OK bits in the LAN Interface Status Word remain off. 4. A PLC fault with text LAN syst em-software fault; resuming occurs. 5. A System log event (Event 2, entry 2 = 0401H) occurs in the Station Manager event log. 6. The following incompatible hardware message is printed to the Station Manager display from the NODE and STAT L commands: This firmware version requires IC693CMM321 -F or later hardware. Your hardware version is incompatible, and the network interf ace is unable to go online. To recover, please use the firmware loader to reload firmware version 2.20. It is available from the PLC Technical Support web page. See the TCP/IP Ethernet Communications for the Series 90 PLC User's Manual for details. To restore correct operation, update the module firmware to version 2.20. If you do not have the version 2.20 field update kit, part number 44A737842-G05, download the file cmm321-r220.zip from the PLC Technical Support web page, unzip the file, and then follow the instructions in cmm321update.doc (included in the ZIP file). System Requirements This version of Ethernet Interface firmware requires IC693 CPU firmware versio n 6.50 or later for full operation. Restricted operation is available with CPU firmware version 5.03 or later (6.03 for the Model 351 CPU). However, Ethernet Interface us ers are strongly urged to update th eir CPU firmware. See the section Additional Restrictions With CPU Firmware Earlier Than Version 6.50. Connecting to PLC programming software via Ethernet requires both IC693 CPU version 6.50 (or later version) and Ethernet Interface version 1.10 or higher. Power Supply Requirements The IC693CMM321 Ethernet Interface module (all versions/styles) will work with any IC693 power supply with the exception that, if used with the IC693PWR321 power supply, you must use Revision K or later of this power supply. Power consumption of the Ethernet Interface module is 700mA @ +5VDC, plus power required by the optional AAUI transceiver. This version of IC693CMM321 hardware does not requi re an AAUI transceiver for operation on 10Base-T networks. If an AAUI transceiver is used (for example, on an optical fiber Ethernet network), be sure to include the +5VDC power required by the transceiver (typically 50 to 350mA) when calculating the total power consumption of the PLC rack. Consult the transcei ver documentation to obtain its power requirements

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248