IC693CMM321 | IC693CMM321-EE

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CMM321 | IC693CMM321-EE

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 Modbus EGD Ethernet Interface TCP/IP Module
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CMM321 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -KN, -KM, -KL, -JL, -JK, -HJ, -GH, -FG, -EF, -EE, -DD, -CD, -CC, -BA,

Product Manual Excerpt

IC693CMM321-EE, with FW version 2.10, Demko approval, See GFK-1085K for other new features and problems resolved July 16, 1998 I MPORTANT P RODUCT I NFORMATION READ THIS INFORMATION FIRST Product: Factory LAN TCP/IP Ethernet Interface IC693CMM321-AE/BE/CE/DE/EE Introduction This document contains information about this product that is not available in any other publication; therefore, we suggest you keep it with your other PLC documentation. This document covers details about Demko Agency approval, firmware release 2.10, and other general items of interest concerning the IC693CMM321 module. This document was revised to correct an error in the Field Update Kit part number. Otherwise, it contains the same information as version GFK-1085J. Demko Agency Approval Beginning with revision level EE, this module was granted Demko Agency approval and will be labeled accordingly. Firmware Release 2.10 This section discusses firmware release 2.10 of the IC693 TCP/ IP Ethernet Interface. This module provides network communications using the SRTP (Service Request Transfer Protocol) over TCP/ IP (Transmission Control Protocol and Internet Protocol) on an Ethernet Local Area Network (LAN). The Interface supports communication between IC693 PLCs and/ or IC697 PLCs equipped with TCP/ IP Ethernet Interfaces. The Interface with IC641 TCP/ IP Ethernet programming software and applications that communicate via the TCP/ IP Host Communications software. See later sections for restrictions. Release 2.10 of this module adds Naming Resolution support. This provides addressability to other IC693CMM321 Interfaces using DDP names, standard DNS (Domain Name Service) names, locally defined ‘nametbl’ names, or IP addresses (addressability is also possible to IC697CMM742 Interfaces). Appendix F in the TCP/IP Ethernet Communications for the IC693 PLC User’s Manual , GFK-1084, gives an overview of Name Resolution. This manual also gives various examples in Chapter 3 on how to use names within Channel requests. Release 2.10 also provides various other enhancements and problem fixes which are identified in sections 3 and 4 of this document. IC693CMM321-AE and IC693CMM321–BE identify units shipped as IC693CMM321-AA and -BA, respectively, and then updated to TCP/IP software version 2.10 using the field update kit identified below. IC693CMM321-AA and IC693CMM321-BA are identical except for CE mark labeling on the latter. I C693CMM321-CE identifies both units shipped as IC693CMM321-CB and IC693CMM321-CC and then updated to TCP/IP software version 2.10 using the field update kit identified below, and units shipped after the effective date of this change. IC693CMM321-DE identifies units shipped as IC693CMM321-DD and then updated to TCP/IP software version 2.10 using the field update kit identified below and units shipped after the effective date of this change. 2 GFK-1085K July 16, 1998 Important Product Information: Factory LAN TCP/IP Ethernet Interface There are no operational differences between IC693CMM321-AB/ -BE and IC693CMM321-DE. There are minor differences during software load operations. See the section Additional Restrictions and Significant Open Issues – Ethernet Interface IC693CMM321-AE or IC693CMM321-BE (Field Update from IC693CMM321-AA or -BA) , for details. Hardware Identification (for release 2.01) EM3A1 - 44A736387-G01 R06 Software Identification IC693CMM321-AE Software Loader Version 1.01 IC693CMM321-BE TCP/IP Version 2.10 IC693CMM321-CE Software Loader Version 1.02 TCP/IP Version 2.10 IC693CMM321-DE Software Loader Version 2.00 TCP/IP Version 2.10 Replaces: IC693CMM-321-DD Field Update Information: This upgrade is optional. For updates, order Field Update Kit: 44A737842-G04 Hardware Compatibility EM3A1 - 44A736387-G01 R04 or later Functional Compatibility Firmware release 2.10 of the IC693 Ethernet Interface is compatible with the following products: H IC693 PLC CPU firmware version 6.50 or later; restricted operation with CPU firmware 5.03 or later (version 6.03 or later for Model 351 and 352 CPU). See the section “Additional Restrictions with CPU Firmware Earlier Than Version 6.50”. H IC641 programming software version 6.01 or later (required to configure the Ethernet Interface). H IC641 TCP/IP Ethernet programming software version 6.50 or later. (required for TCP/IP Ethernet communications to the TCP/IP Ethernet Interface). H Host Communications Toolkit (HCT) software products listed below. (Note that some versions of HCT do not support the ’Send Information Report’ COMMREQ. Please refer to the appropriate HCT IPI document for more information.) H Toolkit for Windows NT r C/C++ Applications (IC641SWP058) H Toolkit for Windows r C/C++ Applications (IC641SWP052) H Toolkit for HP–UX C Applications (IC641SWP054) r Microsoft, Windows, Windows 95, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation. 3 GFK-1085K July 16, 1998 Important Product Information: Factory LAN TCP/IP Ethernet Interface t DEC, VAX, Alpha AXP, and VMS are trademarks of Digital Equipment Corporation. H Toolkit for DEC t VAX t /VMS t C Applications (IC641SWP053) H Toolkit for DEC Alpha AXP t /VMS C/C++ Applications (IC641SWP057) H Host Communication Drivers for Windows NT/95 (IC641SWP080, IC641SWP081) H Host Communication Drivers for Windows (IC641SWP050, IC641SWP051) Product Documentation TCP/IP Ethernet Communications for the IC693 PLC User’s Manual, GFK-1084. TCP/IP Ethernet Communications for the IC693 PLC Station Manager Manual , GFK-1186. Operational Notes System Prerequisites This version of Ethernet Interface firmware requires IC693 CPU firmware version 6.50 or later for full operation. Restricted operation is available with CPU firmware version 5.03 or later (6.03 or later for the Model 351 and 352 CPU). However, Ethernet Interface users are strongly urged to update their CPU firmware. See the section, “Additional Restrictions With CPU Firmware Earlier Than Version 6.50”. IC641 TCP/IP Ethernet for IC693 PLCs requires both IC693 CPU version 6.5 and Ethernet Interface version 1.10 or higher. Power Supply Requirements The Ethernet Interface requires PLC Power Supply IC693PWR321 (Rev. K or later), IC693PWR322, or IC693PWR330. Power consumption of the Ethernet Interface module is 700mA @ +5VDC, plus power required by the AAUI transceiver. When calculating the total power consumption of the PLC rack, be sure to include the +5VDC required by the AAUI transceiver (typically 50 to 350mA) used with each Ethernet Interface; consult the transceiver documentation to obtain its power requirements. If used, also include the +5VDC power required by the RS-485-to -RS-232 Converter (typically 100mA). Configuration Through Serial Port Required Before Using IC641 TCP/IP Ethernet Programming Software Version 6.01 or later of the IC641 programming software (serial connection only) or version 6.50 or later of IC641 TCP/IP Ethernet programming software must be used to configure the Ethernet Interface prior to use. The Ethernet Interface cannot operate on the network until a valid IP address is configured. Two methods are available: 1. Perform the initial configuration using IC641 programming software through the PLC CPU serial port. 2. Connect a serial terminal to the station manager port (port1) of the Ethernet Interface. Then use the CHSOSW command to enter a temporary IP address. The 4 GFK-1085K July 16, 1998 Important Product Information: Factory LAN TCP/IP Ethernet Interface interface can then be reached by the IC641 TCP/IP Ethernet programming software. Refer to TCP/IP Ethernet Communications Station Manager Manual, GFK-1186, for details. Note: This method of assigning an IP address is not recommended when the PLC CPU firmware is older than version 6.50 because an unconfigured Ethernet Interface is unable to operate for two minutes after the PLC is powered on. Proper IP Addressing is Always Essential The Ethernet Interface must be configured with the correct IP Address for proper operation in a TCP/IP Ethernet network. Use of incorrect IP addressing can disrupt network operation. Refer to TCP/IP Ethernet Communications User’s Manual, GFK-1084 for important information on IP addressing. AAUI Cable Attachment Power to the PLC must be turned off whenever the transceiver cable (AAUI cable) is connected or disconnected at the Interface or at the transceiver. Sudden changes in power supply loading caused by connecting or disconnecting the transceiver with power on may result in unexpected operation of the Ethernet Interface, PLC CPU or other modules. Connecting the transceiver with power on may also blow the protective fuse. A blown fuse cannot be replaced in the field; the Ethernet Interface must be returned for repair. SQE Enable The Ethernet Interface requires that the SQE test signal be enabled on the transceiver connecting it to the Ethernet LAN. Make sure your transceiver has SQE enabled. No HHP Support The Hand Held Programmer (IC693PRG300) may not be used to configure the Ethernet Interface. Do not attempt to configure the Ethernet Interface or to read its configuration with the HHP. Such attempts may result in erroneous Loss-of-Module faults in the PLC Fault Table or other unexpected behavior. Serial Load/Store of Register Table Causes the IC641 TCP/IP Ethernet Programmer To Lose Communication A load or store of the PLC Register (%R) table from the IC641 programmer connected through the CPU serial port can cause Ethernet applications that use the PLC programmer communication window to lose communication. This condition occurs when the load/store operation requires more than 10 seconds to complete. For example, transferring the %R table of a CPU 341 or CPU 351 at 19,200 baud or less will cause the timeout. The Ethernet Interface posts two or more PLC faults with the text “LAN system-software fault; resuming”, and fault-specific data starting with 080008 and/or 080042. In addition, faults with text “Bad remote application request; discarded request” (1B0021) and “Local request to send rejected; discarded request” (110005) may occur. The STAT LED on the Ethernet Interface goes out. IC641 TCP/IP Ethernet Programmer Briefly Loses Communication When Configuration Cleared or Stored Clearing or storing the PLC configuration causes the IC641 TCP/IP Ethernet programming software to display a flashing “NO COMMUNICATIONS” message for 5 GFK-1085K July 16, 1998 Important Product Information: Factory LAN TCP/IP Ethernet Interface one or two seconds. PLC faults similar to those listed under the section, “ Serial Load/Store of Register Table Causes Ethernet Programmers To Lose Communication ” , above occur, and the STAT LED on the Ethernet Interface goes out. In some cases, a ten second delay occurs before loss of communication is detected. When the PLC configuration is stored from the IC641 TCP/IP Ethernet programming software, the communications loss occurs immediately after successful completion of the store. Attempts to store a configuration plus logic and/or reference tables in one operation can fail. However, storing a configuration separately from logic or reference tables will always succeed. Clearing Slot Configuration Closes TCP Connections When the PLC CPU contains version 6.50 or later firmware, clearing the slot configuration of the Ethernet Interface causes the interface to close all of its TCP connections immediately. The Ethernet Interface slot configuration is cleared when the IC641 programming software clears the PLC configuration, or stores

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248