IC693CMM321 | IC693CMM321-CD

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693CMM321 | IC693CMM321-CD

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 Modbus EGD Ethernet Interface TCP/IP Module
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693CMM321 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -KN, -KM, -KL, -JL, -JK, -HJ, -GH, -FG, -EF, -EE, -DD, -CD, -CC, -BA,

Product Manual Excerpt

IC693CMM321-CD, with FW version 2.00, Adds support for Unsolicited Messages October 28, 1996 I MPORTANT P RODUCT I NFORMATION READ THIS INFORMATION FIRST Product: Factory LAN TCP/IP Ethernet Interface IC693CMM321-CD This is release 2.00 of the IC693 TCP/IP Ethernet Interface. This module provides network communications using the SRTP (Service Request Transfer Protocol) over TCP/IP (Transmission Control Protocol and Internet Protocol) on an Ethernet Local Area Network (LAN). The Interface supports communication between IC693 PLCs and/or IC697 PLCs (equipped with Ethernet Interface, IC697CMM741, and TCP/IP software, IC697ENS042). Also, the Interface now supports communication to IC641 TCP/IP Ethernet programming software. The Ethernet Interface can respond to applications that communicate via the TCP/IP Host Communications software. See later sections for restrictions. Release 2.00 of this module adds support for the Unsolicited Message feature and for automatic initialization of IP addressing information using the BOOTP bootstrap protocol. The Unsolicited Message feature adds COMMREQ support to the IC693 ladder language to allow intercommunication initiated from the IC693 PLC to a remote TCP/IP Host Communication Toolkit (HCT) software application. Support for transmission and receipt of remote station manager commands over the User Datagram Protocol (UDP) is also added with this release. IC693CMM321-CD identifies both units shipped as IC693CMM321-CB and IC693CMM321-CC and then updated to TCP/IP software version 2.00 using the field update kit 44A737842-G03, and units shipped after the effective date of this change. Compatibility Release 2.00 of the IC693 Ethernet Interface is compatible with the following products: H IC693 PLC CPU firmware version 6.50 or later; restricted operation with CPU firmware 5.03 or later (version 6.03 or later for Model 351 CPU). See the section “ Additional Restrictions with CPU Firmware Earlier Than Version 6.50”. H IC641 programming software version 6.01 or later (required to configure the Ethernet Interface). H IC641 TCP/IP Ethernet programming software version 6.50 or later. (required for TCP/IP Ethernet communications to the TCP/IP Ethernet Interface). 2 GFK-1085F October 28, 1996 Important Product Information: Factory LAN TCP/IP Ethernet Interface H Host Communications Toolkit software products, listed below. Note that applications built using previous releases of Toolkit products can successfully communicate only to IC697 Ethernet Interfaces. Applications must be relinked using the proper Toolkit release in order to communicate with the IC693 Ethernet Interface. (Once rebuilt, such applications may communicate interchangeably with both IC697 and IC 693 PLCs.) Refer to Host Communications Toolkit Important Product Information document (GFK-0871) for further details, including component version numbers. h Toolkit for Microsoft R Windows R C/C++ Applications (IC641SWP052D or later) h Toolkit for Windows NT C/C++ Applications (IC641SWP058B or later) h Toolkit for HP-UX C Applications (IC641SWP054B or later) h Toolkit for DEC t VAX/VMS C Applications (IC641SWP053B or later) h Toolkit for DEC Alpha AXP/VMS C/C++ Application (IC641SWP057B or later) h Host Communication Drivers for Windows (qty.1: IC641SWP050D; qty.10 - IC641SWP051D) Product Documentation TCP/IP Ethernet Communications for the IC693 PLC User’s Manual, GFK-1084. TCP/IP Ethernet Communications for the IC693 PLC Station Manager Manual , GFK-1186. Operational Notes System Prerequisites This version of Ethernet Interface firmware requires IC693 CPU firmware version 6.50 or later for full operation. Restricted operation is available with CPU firmware version 5.03 or later (6.03 or later for the Model 351 CPU). However, Ethernet Interface version 2.00 users are strongly urged to update their CPU firmware. See section, “Additional Restrictions With CPU Firmware Earlier Than Version 6.50”. IC641 TCP/IP Ethernet for IC693 PLCs requires both IC693 CPU version 6.5 and Ethernet Interface version 1.10 or higher. Power Supply Requirements The Ethernet Interface requires PLC Power Supply IC693PWR321 (Rev. K or later) or IC693PWR322. R Microsoft and Windows are registered trademarks of Microsoft Corporation. t DEC, VAX, Alpha AXP , and VMS are trademarks of Digital Equipment Corporation. 3 GFK-1085F October 28, 1996 Important Product Information: Factory LAN TCP/IP Ethernet Interface Power consumption of the Ethernet Interface module is 700mA @ +5VDC, plus power required by the AAUI transceiver. When calculating the total power consumption of the PLC rack, be sure to include the +5VDC required by the AAUI transceiver (typically 50 to 350mA) used with each Ethernet Interface; consult the transceiver documentation to obtain its power requirements. If used, also include the +5VDC power required by the RS-485-to -RS-232 Converter (typically 100mA). Configuration Through Serial Port Required Before Using IC641 TCP/IP Ethernet Programming Software Version 6.01 or later of the IC641 programming software (serial connection only) or version 6.50 or later of IC641 TCP/IP Ethernet programming software must be used to configure the Ethernet Interface prior to use. The Ethernet Interface cannot operate on the network until a valid IP address is configured. Two methods are available: 1. Perform the initial configuration using IC641 programming software through the PLC CPU serial port. 2. Connect a serial terminal to the station manager port (port1) of the Ethernet Interface. Then use the CHSOSW command to enter a temporary IP address. The interface can then be reached by the IC641 TCP/IP Ethernet programming software. Refer to TCP/IP Ethernet Communications Station Manager Manual, GFK-1186, for details. Note: This method of assigning an IP address is not recommended when the PLC CPU firmware is older than version 6.50 because an unconfigured Ethernet Interface is unable to operate for two minutes after the PLC is powered on. Proper IP Addressing is Always Essential The Ethernet Interface must be configured with the correct IP Address for proper operation in a TCP/IP Ethernet network. Use of incorrect IP addressing can disrupt network operation. Refer to TCP/IP Ethernet Communications User’s Manual, GFK-1084 for important information on IP addressing. AAUI Cable Attachment Power to the PLC must be turned off whenever the transceiver cable (AAUI cable) is connected or disconnected at the Interface or at the transceiver. Sudden changes in power supply loading caused by connecting or disconnecting the transceiver with power on may result in unexpected operation of the Ethernet Interface, PLC CPU or other modules. Connecting the transceiver with power on may also blow the protective fuse. A blown fuse cannot be replaced in the field; the Ethernet Interface must be returned for repair. SQE Enable The Ethernet Interface requires that the SQE test signal be enabled on the transceiver connecting it to the Ethernet LAN. Make sure your transceiver has SQE enabled. 4 GFK-1085F October 28, 1996 Important Product Information: Factory LAN TCP/IP Ethernet Interface No HHP Support The Hand Held Programmer (IC693PRG300) may not be used to configure the Ethernet Interface. Do not attempt to configure the Ethernet Interface via th

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248