IC693BEM340 | IC693BEM340-CE

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693BEM340 | IC693BEM340-CE

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 FIP Bus Controller Mod. IC693BEM
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693BEM340 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -CE, -CD, -EF, -EG,

Product Manual Excerpt

Upgrading the Bus Controller Firmware To upgrade the Bus Controller firmware, connect the loading computer (PC) with the new firmware to the (15-pin) serial port on the front of the Bus Controller. From the loading PC, invoke the Loading Utility and follow its instructions to update the firm- ware. 3 section level 1 3-1 GFK-1213 Chapter 3 Hand-held Programmer Configuration This chapter describes configuration steps for the Bus Controller using a Hand-held Programmer (HHP). The module must be physically present to be configured by the HHP. The HHP may be used to enter, change, or remove a configuration. The Hand–Held Programmer must be connected to the power supply module and be connected to the PLC. The PLC power must be ON and the PLC in STOP mode. The FIP Bus Controller (FBC) must be installed in the desired slot. Configuration of the FIP Bus Controller (FBC) includes choosing the Configuration mode and setting its parameters. Mode 10 Mode 11 FIP Bus Controller (FBC) slot number in the PLC rack Configuration mode 10 Configuration mode 11 Communication protocol (FIP/WorldFIP) and Tslot Subscriber number and medium number Maximum time between input scans by the CPU module Not applicable Bus arbiter (BA) version numbers and external configuration numbers Addresses in %I PLC memory of 16 validity bits of consumed COMV’s (1= invalid) and of the module status register. Addresses in %I PLC memory of 16 validity bits of input areas (1=invalid) and of the module status register Size and addresses in %R PLC memory of the input area ( %RI ), updated based on COMV’s consumed by the module Size and addresses in PLC memory of each of the 16 input areas, updated based on COMV’s consumed by the module Size and addresses in PLC memory %R of the output area ( %RQ ), used to build the COMV’s produced by the module Size and addresses in PLC memory of each of the 16 output areas, used to build the COMV’s produced by the module Not applicable Configuration of COMV (9 maximum): H type of COMV (absent, produced or consumed), H COMV identifier, H refresh or promptness period associated with the COMV, H constitution of the COMV, including for each TVA (3 max): h type of TVA, h length of TVA, h position of TVA, h number of area containing TVA, h offset in area from which TVA is stored. Not applicable Configuration of COMV Statfbc: H presence of COMV (absent or produced), H COMV identifier, H refresh period associated with the COMV. Configuration data is stored in the PLC. The configuration is static. It cannot be changed while the PLC is operating. 3 3-2 GFK-1213 Series 90 t -30 FIP Bus Controller User’s Manual – March 1996 Setting the PLC to Stop Mode If necessary, press the RUN key of the Hand–Held Programmer (HHP) to set the PLC to STOP mode. PRESS<–/+>KEY

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248