IC693APU300 | IC693APU300G

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693APU300 | IC693APU300G

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 4 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 High Speed Counter
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693APU300 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

Input characteristics The High Speed Counter uses s ingle - ended posit ive logic (source) type inputs.  Transducers with CMOS buffer outputs (74HC04 equivalent) can directly drive the High Speed Counter inputs using the 5 V input range.  Transducers using open collector outputs must include a 470  pullup r esistor to 5V to guarantee compatibility with the High Speed Counter inputs.  Transducers using high voltage open collector (sink) type outputs must have a 1K pullup resistor to +12 V for compatibility with the High Speed Counter 10 to 30 volt input range. Note: Classic versions of the APU300 required that transducers using TTL totem pole include a 470  pull - up resistor (to 5 V) to guarantee compatibility with the High - speed Counter inputs. Enhanced ( IC693APU300 - MA and later versions ) do not require a 470  pull - up resistor with transducers using TTL totem pole outputs . 6 High - Speed Counter Module GFK - 2602 B Input voltage range s The default voltage range is 10 to 30 Vdc . To use this voltage range, leave the threshold selection terminals (pins 13 and 15) unconnected . To select t he 5 Vdc thresho ld , connect a jumper between two terminals on the detachable terminal board connector. Caution Do not connect 10 to 30 Vdc to the module inputs when the 5 Vdc input range (pins 13 and 15 jumpered) is selected. Doing so will damage the module. Terminals Field Wiring I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I 11 I12 5V OPTION + - Q1 Q2 Q3 Q4 1 3 5 7 9 11 13 15 17 19 2 4 6 8 10 12 14 16 18 20 + - High - Speed Counter Module 7 GFK - 2602 B Terminal Assignments for Each Counter Type The table below lists termina l block pin assignments based on the counter type combinations and input mode setting

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248