IC693APU300 | IC693APU300F

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693APU300 | IC693APU300F

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 4 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 High Speed Counter
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693APU300 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

4 High - Speed Counter Module GFK - 2602 B Indicators (S1) MODULE OK GREEN The High Speed Counter is powered up and has completed its internal diagnostics. RED The watchdog timer circuit has detected a module failure. OFF Module is not powered up correctly or internal diagnostics failed. (S2) CONFIG ON A user configuration has been downloaded to the module. OFF A configuration has not been downloaded; the default configuration is in effect. (S3) FIELD POWER ON Output Field Power Present OFF Output Field Power not present (1 - 12) INPUT STATUS ON Input is ON OFF Input is OFF (1 - 4) OUTPUT STATUS ON Output is ON AMBER Output has overcurrent fault. OFF Output is OFF Module Status Data The Module Status data provides the CPU with 16 bits of diagnostic information about module operation. Bit Type A Type B (1) Type C (1) 1 Strobe 1 flag Strobe 1.1 flag Strobe 1.1 flag 2 Strobe 2 flag Strobe 1.2 flag Strobe 1.2 flag 3 Strobe 3 flag Strobe 2.1 flag Strobe 1.3 flag 4 Strobe 4 flag Strobe 2.2 flag Home Found 5 Preload 1 flag Preload 1 flag Preload 1.1 flag 6 Preload 2 flag Preload 2 flag Preload 1.2 flag 7 Preload 3 flag Disable 1 status Disable status 8 Preload 4 flag Disable 2 status Home Input status 9 Output 1 status Output 1.1 status Output 1.1 status 10 Output 2 status Output 1.2 status Output 1.2 status 11 Output 3 status Output 2.1 status Output 1.3 status 12 Output 4 status Output 2.2 status Output 1.4 status 13 Module Ready Module Ready Module Ready 14 always off always off always off 15 always off always off always off 16 Error flag Error flag Error flag (1) A number in the format x.x identifies the counter and the element number. For example, Strobe 1.2 indicates Counter 1, Strobe 2. External input point s External output point s High - Speed Counter Module 5 GFK - 2602 B Counter Status Data Counter Status data is bit - type data that indicates the status of counter operations. Depending on the type of counter some bits may not be used. Unused bits are always 0. Bit Field Name Bit Number Length Default Value Field Description Strobe 1 Status 0 1 Bit 0 0 – Strobe Has Not Occurred, 1 – Strobe Has Occurred Strobe 2 Status 1 1 Bit 0 Strobe 3 Status 2 1 Bit 0 Home Input Status 3 1 Bit 0 0 – No Home Input, 1 – Home Input Present. Preload 1 Status 4 1 Bit 0 0 – Preload Has Not Occurred 1 – Preload Has Occurred Preload 2 Status 5 1 Bit 0 Disable Status 6 1 Bit 0 0 – No Disable Input, 1 – Disable Input Present. Preset 1 Compare Status 7 1 Bit 0 0 – Preset is Off, 1 – Preset is On Preset 2 Compare Status 8 1 Bit 0 Preset 3 Compare Status 9 1 Bit 0 Preset 4 Compare Status 10 1 Bit 0 Reserved 11 1 Bit 0 Reserved. Rollover Detection Flag 12 1 Bit 0 0 – Rollover Has Not Occurred, 1 – Rollover Has Occurred. Reserved 13 2 Bit s 0 Reserved. Home Found 15 1 Bit 0 0 – Home Not Found, 1 – Home Found Field W iring T o meet the European EMC Directive requirements, shielded cable must be used for all cables connecting to the IC69 3 APU300 High Speed Counter. The shielded cable must have a high frequency ground within 6 inches (15.24 cm) of the IC69 3 APU300 module. Refer to Appendix B in GFK 1179, Installation Requirements for Conformance to Standards for cable clamping assembly to ground shielded cables. The cable’s length is limited to

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248