IC693ALG392 | IC693ALG392-BD

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693ALG392 | IC693ALG392-BD

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 5 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: GE Fanuc Series 90-30 High Density Analog Output Voltage or Current 8 Channels
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693ALG392 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -CF, -BE, -BD,

Product Manual Excerpt

C693ALG392-BD, IC694ALG392-BB PACSystems™ RX3i and Series 90-30 Series 90-30 Analog Output Module, Current/Voltage, 8 Channel, IC693ALG392 GFK-2557 RX3i Analog Output Module, Current/Voltage, 8 Channel, IC694ALG392 January 20 10 MODULE 0 K USER SUPPL Y IC694ALG392 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 The 8–Channel Analog Current/Voltage Output module; IC69*ALG392, provides up to eight single-ended output channels with current loop outputs and/or voltage outputs. Each output channel can be set up using the configuration software for any of these ranges: ▪ 0 to + 1 0 volts (unipolar) ▪ - 1 0 to + 1 0 volts (bipolar) ▪ 0 to 20 milliamps ▪ 4 to 20 milliamps Each channel is capable of converting 1 5 to 1 6 bits (depending on the range selected) of binary data to an analog output. All eight channels are updated every 8 milliseconds. In current modes, the module reports an Open Wire fault to the CPU for each channel. The module can go to a known last state when system power is interrupted. As long as external power is applied to the module, each output will maintain its last value or reset to zero, as configured. This module can be installed in any I/O slot of an RX3i system. Isolated +24 VDC Power The module must receive its 24 VDC power from an external source, which must be connected directly to the module’s terminal block. 2 Analog Output Modules, Current/Voltage, 8 Channel, IC693ALG392 and IC694ALG394 GFK-2557 Specifications: ALG392 Number of Output Channels 1 to 8 selectable, single–ended Output Current Range 4 to 20 mA and 0 to 20 mA Output Voltage Range 0 to 1 0 V and – 1 0 V to + 1 0 V Calibration Factory calibrated to .625 μA for 0 to 20 mA; 0.5 μA for 4 to 20 mA; and .3 1 25 mV for voltage (per count) User Supply Voltage (nominal) +24 VDC, from user supplied voltage source External Supply Voltage Range 20 VDC to 30 VDC Power Supply Rejection Ratio (PSRR) Current Voltage 5 μA/V (typical), 1 0 μA/V (maximum) 25 mV/V (typical), 50 mV/V (maximum) External Power Supply Voltage Ripple 1 0% (maximum) Internal Supply Voltage +5 VDC from PLC backplane Update Rate 8 milliseconds (approximate, all eight channels) Determined by I/O scan time, application dependent. Resolution: 4 to 20mA: 0.5 μA ( 1 LSB = 0.5 μA) 0 to 20mA: 0.625 μA ( 1 LSB = 0.625 μA) 0 to 10V: 0.3 1 25 mV ( 1 LSB = 0.3 1 25 mV) -10 to +10V: 0.3 1 25 mV ( 1 LSB = 0.3 1 25 mV) Absolute Accuracy: * Current Mode +/-0. 1 % of full scale @ 25°C (77°F), typical +/-0.25% of full scale @ 25°C (77°F), maximum +/-0.5% of full scale over operating temperature range (maximum) Voltage Mode +/-0.25% of full scale @ 25°C (77°F), typical +/-0.5% of full scale @ 25°C (77°F), maximum +/- 1 .0% of full scale over operating temperature range (maximum) Maximum Compliance Voltage V USER –3 V (minimum) to V USER (maximum) User Load (current mode) 0 to 850 Ω (minimum at V USER = 20 V, maximum 1 350 Ω at V USER = 30 V) (Load less than 800 Ω is temperature dependent.) Output Load Capacitance (current mode) 2000 pF (maximum) Output Load Inductance (current mode) 1 H Output Loading (voltage mode) Output load Capacitance 5 mA (2 K Ohms minimum resistance) ( 1 μF maximum capacitance) Isolation, Field to Backplane (optical) and to frame ground 250 VAC continuous; 1 500 VAC for 1 minute Power Consumption 11 0 mA from +5 VDC PLC backplane supply 3 1 5 mA from +24 VDC user supply Refer to the PACSystems RX3i Systems Manual , GFK-23 1 4, for product standards and general specifications. In order to meet the levels for RF Susceptibility specified in Appendix A of the PACSystems RX3i System Manual, GFK-23 1 4, when this module is present, the system must be mounted in a metal enclosure. ▪ In the presence of severe RF interference, accuracy may be degraded to ± 1 % FS for current outputs and ± 3% FS for voltage outputs.

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248