IC693ALG223 | IC693ALG223-EA

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

product-image

IC693ALG223 | IC693ALG223-EA

  • Availability: In StockShips Today!
  • Units in Stock: Immediate Availablity: 6 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: Analog Input 16
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693ALG223 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -GB, -EA,

Product Manual Excerpt

1 In the presence of severe Radiated RF interference (IEC 61000-4-3, 10V/m), accuracy may be degraded to ±5% of full scale. 2 In the presence of severe Conducted RF interference (IEC 61000-4-6, 10Vrms), accuracy may be degraded to ±0.5% of full scale. Refer to the applicable manual for product standards, general operating specifications, and installation requirements: Series 90-30 Installation Manual, GFK-0356 Series 90-30 systems: Installation Requirements for Conformance to Standards, GFK-1179 PACSystems RX3i System Manual, GFK-2314 Analog Current Input Module – 16 Channel 3 GFK-2655A Configuration: ALG223 Module ALG223 is configured with the configuration software. Its configurable parameters are described below. Module Settings Parameter Choices Description Active Channels 1 to 16 The number of channels to be scanned. Channels are scanned in sequential, contiguous order. Channel Value Reference Address Valid memory type: %AI The starting address for input data from the module. Channel Value Reference Length Read-only. Each channel provides 16 bits (1 word) of analog input data to the Controller CPU. Module Status Reference Address Valid memory type: %I The starting address for status information from the module. Module Status Reference Length 0, 8, 16, 24, 32, 40 The number of status bits (0 to 40) reported to the Controller CPUWhen set to 0, status reporting is disabled. To enable status reporting, set this parameter to a value other than 0. Data formats are shown on page 5. I/O Scan Set 1 through 32 Assigns the module to an I/O Scan Set defined in the CPU configuration. Input Channel Data Parameter Choices Description Range 4-20 mA (default), 0-20 mA, or 4-20 mA enhanced In the 4-20 mA range, input currents from 4 to 20 mA are reported to the CPU as values from 0 to 32000 units. In the 0 to 20 mA range, input currents from 0 to 20 mA are reported to the CPU as values from 0 to 32000 units. In the 4 to 20 mA enhanced range, currents from 4 to 20 mA are reported to the CPU as values form 0 to 32000 units. Currents below 4 mA are reported as negative values with 0 represented as –8000 units. Alarm Low (Engineering Units) 4-20 mA = 0 to 32759 Each channel can be assigned a low alarm

Warning: include_once(/js/tracking.php): failed to open stream: No such file or directory in /var/www/series/revision.php on line 248 Warning: include_once(): Failed opening '/js/tracking.php' for inclusion (include_path='.:/usr/share/php:/usr/share/pear') in /var/www/series/revision.php on line 248